Influence of stent properties on the alteration of cerebral intra-aneurysmal haemodynamics:: flow quantification in elastic sidewall aneurysm models

被引:40
作者
Baráth, K
Cassot, F
Fasel, JHD
Ohta, M
Rüfenacht, DA
机构
[1] Hop Cantonal Geneva, Dept Radiol, CH-1211 Geneva, Switzerland
[2] CHU Purpan, Funct Neuroimaging Lab, INSERM, U455, Toulouse, France
[3] Med Univ Geneva, Dept Anat, Geneva, Switzerland
关键词
cerebral; aneurysm; stent; haemodynamics; in vitro;
D O I
10.1179/016164105X35477
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives: Stent implantation across the neck of cerebral aneurysms may induce intra-aneurysmal flow reduction, and consequently saccular thrombosis and vessel wall repair. To analyse the influence of different stent parameters on such flow reduction, we studied the flow changes in vascular models, induced by a series of stents. Methods: Two different neck-sized elastic sidewall aneurysm models were connected to a circulatory loop. Twenty different stents were introduced in both models to analyse the effect of their parameters, such as porosity, filament diameter and permeability. Flow patterns were visualized by using glass particles and laser sheet translumination. The digitally recorded data were transferred for computer analysis. The changes of the vortex velocity for each stent model combination were investigated and statistically evaluated. Results: Intra-aneurysmal flow analysis showed dispersion of the vortices of a variable degree, and velocity reduction of 30% mean in model 1 an 49% mean in model 2. By statistical analysis three groups of stents (best', 'medium' ' 'worst) were identified, according to their haemodynamic efficacy. No correlations were observed between the haemodynamic performance of the stents and the porosity, filament diameter and permeability values separately. The stent effects were on average more important in the large-necked than in the small-necked aneurysm model. Discussion: Stent implantation induces intra-aneurysmal loss of vortex coherence and flow reduction. The analysed stent parameters show complex interrelationship, including also stent 'design'. The difference in the haemodynamic efficacy of the individual stents between the two models raises the question of 'stent positioning effects'.
引用
收藏
页码:S120 / S128
页数:9
相关论文
共 39 条
[1]   Modeling of flow in a straight stented and nonstented side wall aneurysm model [J].
Aenis, M ;
Stancampiano, AP ;
Wakhloo, AK ;
Lieber, BB .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (02) :206-212
[2]  
Baráth K, 2004, AM J NEURORADIOL, V25, P1750
[3]  
BLACK B K, 1952, U S Armed Forces Med J, V3, P1813
[4]   OBSERVATIONS ON THE RELATIONSHIP BETWEEN THE VOLUME AND THE SIZE OF THE ORIFICE OF EXPERIMENTAL ANEURYSMS [J].
BLACK, SPW ;
GERMAN, WJ .
JOURNAL OF NEUROSURGERY, 1960, 17 (06) :984-990
[5]   Intravascular stent placement for a fusiform aneurysm of the posterior cerebral artery: case report [J].
Brassel, F ;
Rademaker, J ;
Haupt, C ;
Becker, H .
EUROPEAN RADIOLOGY, 2001, 11 (07) :1250-1253
[6]   COMPUTER MODELING OF INTRACRANIAL SACCULAR AND LATERAL ANEURYSMS FOR THE STUDY OF THEIR HEMODYNAMICS [J].
BURLESON, AC ;
STROTHER, CM ;
TURITTO, VT .
NEUROSURGERY, 1995, 37 (04) :774-782
[7]   POSTOPERATIVE ANGIOGRAPHY AND SLIPPED CLIP [J].
DRAKE, CG ;
ALLCOCK, JM .
JOURNAL OF NEUROSURGERY, 1973, 39 (06) :683-689
[8]  
Foutrakis GN, 1999, AM J NEURORADIOL, V20, P1309
[9]  
GEREMIA G, 1994, AM J NEURORADIOL, V15, P1223
[10]  
GONZALEZ CF, 1992, AM J NEURORADIOL, V13, P181