Continuous glucose monitoring in interstitial subcutaneous adipose tissue and skeletal muscle reflects excursions in cerebral cortex

被引:33
作者
Nielsen, JK
Djurhuus, CB
Gravholt, CH [1 ]
Carus, AC
Granild-Jensen, J
Orskov, H
Christiansen, JS
机构
[1] Aarhus Univ Hosp, Med Dept Endocrinol & Diabet M, DK-8000 Aarhus, Denmark
[2] Aarhus Univ Hosp, Med Res Labs, DK-8000 Aarhus, Denmark
关键词
D O I
10.2337/diabetes.54.6.1635
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Continuous glucose monitoring (CGM) is being explored using several types of glucose sensors. Some are designed for subcutaneous adipose tissue. It is important to determine to which extent these glucose fluctuations in different tissues reflect changes taking place in the central nervous system, where glucose sensing is thought to occur. We studied the ability of subcutaneous adipose interstitial fluid measurements to parallel glucose propagations in blood, muscle, and central nervous system (CNS) during hyper- and hypoglycemia. A subcutaneous CGM system was applied in the CNS, subcutaneous adipose tissue, and skeletal muscle of nine Vietnamese potbellied pigs, and data were compared with frequent sampling in blood. Alterations in glucose levels were induced with intravenous glucose and insulin. During hyperglycemia, no difference was detected in delay between blood and interstitial glucose levels in subcutaneous adipose tissue (18.0 +/- 0.8 min), muscle (18.0 +/- 0.9 min), and CNS (20.3 +/- 1.2 min), respectively. During hypoglycemia, we found no time difference between interstitial parameters in the three tissues. However, the amplitude of glucose changes varied considerably, with a smaller magnitude of glucose change taking place in the brain. The timing of glucose excursions in subcutaneous adipose tissue and muscle reflect excursions in CNS. The reduced magnitude of glucose excursions in the brain suggests that different mechanisms of glucose transport are operative in CNS compared with subcutaneous adipose tissue and muscle.
引用
收藏
页码:1635 / 1639
页数:5
相关论文
共 23 条
[1]   Moderate controlled cortical contusion in pigs: Effects on multi-parametric neuromonitoring and clinical relevance [J].
Alessandri, B ;
Heimann, A ;
Filippi, R ;
Kopacz, L ;
Kempski, O .
JOURNAL OF NEUROTRAUMA, 2003, 20 (12) :1293-1305
[2]   Brain metabolism during cardiopulmonary resuscitation assessed with microdialysis [J].
Bahlmann, L ;
Klaus, S ;
Baumeier, W ;
Schmucker, P ;
Raedler, C ;
Schmittinger, CA ;
Wenzel, V ;
Voelckel, W ;
Lindner, KH .
RESUSCITATION, 2003, 59 (02) :255-260
[3]   Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor [J].
Boyne, MS ;
Silver, DM ;
Kaplan, J ;
Saudek, CD .
DIABETES, 2003, 52 (11) :2790-2794
[4]  
FELLOWS LK, 1992, J NEUROCHEM, V59, P2141
[5]   ASSESSMENT OF SUBCUTANEOUS GLUCOSE-CONCENTRATION - VALIDATION OF THE WICK TECHNIQUE AS A REFERENCE FOR IMPLANTED ELECTROCHEMICAL SENSORS IN NORMAL AND DIABETIC DOGS [J].
FISCHER, U ;
ERTLE, R ;
ABEL, P ;
REBRIN, K ;
BRUNSTEIN, E ;
VONDORSCHE, HH ;
FREYSE, EJ .
DIABETOLOGIA, 1987, 30 (12) :940-945
[6]   Extracellular glucose turnover in the striatum of unanaesthetized rats measured by quantitative microdialysis [J].
Fray, AE ;
Boutelle, M ;
Fillenz, M .
JOURNAL OF PHYSIOLOGY-LONDON, 1997, 504 (03) :721-726
[7]   Physiological levels of glucagon do not influence lipolysis in abdominal adipose tissue as assessed by microdialysis [J].
Gravholt, CH ;
Moller, N ;
Jensen, MD ;
Christiansen, JS ;
Schmitz, O .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2001, 86 (05) :2085-2089
[8]   Glycogen: The forgotten cerebral energy store [J].
Gruetter, R .
JOURNAL OF NEUROSCIENCE RESEARCH, 2003, 74 (02) :179-183
[9]   Direct measurements of the permeability surface area for insulin and glucose in human skeletal muscle [J].
Gudbjörnsdóttir, S ;
Sjöstrand, M ;
Strindberg, L ;
Wahren, J ;
Lönnroth, P .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2003, 88 (10) :4559-4564
[10]   Effects of glucose and insulin levels on adipose tissue glucose measurement by microdialysis probes retained for three weeks in Type 1 diabetic patients [J].
Hullegie, LM ;
Lutgers, HL ;
Dullaart, RPF ;
Sluiter, WJ ;
Wientjes, KJ ;
Schoonen, AJM ;
Hoogenberg, K .
NETHERLANDS JOURNAL OF MEDICINE, 2000, 57 (01) :13-19