An improved, computer-based method to automatically track internal and external diameter of isolated microvessels

被引:52
作者
Davis, MJ [1 ]
机构
[1] Texas A&M Univ Syst Hlth Sci Ctr, Cardiovasc Res Inst, Dept Med Physiol, College Stn, TX 77845 USA
关键词
automated diameter tracking; vascular diameter measurements; video dimension analyzer;
D O I
10.1080/10739680590934772
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective:To develop an automated diameter tracking method suitable for studies of isolated, perfused microvessels (<100 mu m internal diameter (ID)). Methods: A diameter tracking method was implemented in conjunction with a standard PC workstation and video card. Within a user-defined window, the algorithm combined thresholding and iterative regression procedures to detect the average outer diameter (OD) of a vertically oriented microvessel. After an initial ID measurement by the user. the program continuously calculated ID based on the assumption of an incompressible vessel wall. Results: The program, Vessel Track, was tested against a manual video caliper and two analog video dimension analyzers. Vessel Track was capable of accurately following arteriolar dimensions during extreme vasodilation and vasoconstriction. It provided more accurate, lower-noise recordings than either of the video dimension analyzers particularly after strong vasoconstriction during which lumenal folds developed. Vessel Track also was capable of accurately measuring large-amplitude vasomotion in isolated lymphatic vessels at a tracking frequency of similar to 30 times/s. Conclusions: Vessel Track should be useful for automated diameter tracking of isolated arterioles, venules, and lymphatics. With suitable preparations, it provides fast, stable measurements of 11) in microvessels even with irregular lumen geometry.
引用
收藏
页码:361 / 372
页数:12
相关论文
共 27 条
[1]  
CARO CG, 1978, SOLID MECH PROPERTIE, P86
[2]   LENGTH-TENSION RELATIONSHIP OF VASCULAR SMOOTH-MUSCLE IN SINGLE ARTERIOLES [J].
DAVIS, MJ ;
GORE, RW .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 256 (03) :H630-H640
[3]   Force-velocity relationship of myogenically active arterioles [J].
Davis, MJ ;
Davidson, J .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2002, 282 (01) :H165-H174
[4]   MODULATION OF BAT WING VENULE CONTRACTION BY TRANSMURAL PRESSURE CHANGES [J].
DAVIS, MJ ;
SHI, XP ;
SIKES, PJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 262 (03) :H625-H634
[5]  
DEVANEY MJ, 1976, ISA T, V15, P73
[6]   METHODS FOR ISOLATION, CANNULATION, AND INVITRO STUDY OF SINGLE MICRO-VESSELS [J].
DULING, BR ;
GORE, RW ;
DACEY, RG ;
DAMON, DN .
AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 241 (01) :H108-H116
[7]   Relation between outer and luminal diameter in cannulated arteries [J].
Faury, G ;
Maher, GM ;
Li, DY ;
Keating, MT ;
Mecham, RP ;
Boyle, WA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 277 (05) :H1745-H1753
[8]  
FUNG YC, 1990, STRESS STRAIN STABIL, P382
[9]   Inhibition of the active lymph pump by flow in rat mesenteric lymphatics and thoracic duct [J].
Gashev, AA ;
Davis, MJ ;
Zawieja, DC .
JOURNAL OF PHYSIOLOGY-LONDON, 2002, 540 (03) :1023-1037
[10]  
Goodman A., 1988, INNOV TECH BIOL MED, V9, P350