Reliability of treadmill exercise testing in older patients with chronic hemiparetic stroke

被引:59
作者
Dobrovolny, CL
Ivey, FM
Rogers, MA
Sorkin, JD
Macko, RF
机构
[1] Baltimore VA Med Ctr, Geriatr Serv, Dept Neurol, Baltimore, MD 21201 USA
[2] Univ Maryland, Sch Med, Div Gerontol, Baltimore, MD 21201 USA
[3] Univ Maryland, Coll Hlth & Human Performance, Dept Kinesiol, College Pk, MD 20742 USA
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2003年 / 84卷 / 09期
关键词
exercise test; hemiparesis; rehabilitation; reliability and validity; stroke;
D O I
10.1016/S0003-9993(03)00150-3
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To assess the test-retest reliability of cardiopulmonary measurements during peak effort and submaximal treadmill walking tests in older patients with gait-impaired chronic hemiparetic stroke. Design: Nonrandomized test-retest. Setting: Hospital geriatric research stress testing laboratory. Participants: Fifty-three subjects (44 men, 9 women; mean age, 65+/-8y) with chronic hemiparetic gait after remote (>6mo) ischemic stroke. Patients had mild to moderate chronic hemiparetic gait deficits, making handrail support necessary during treadmill walking. Interventions: Peak effort and submaximal effort treadmill walking tests were conducted and then repeated on a separate day at least a week later. Main Outcome Measures: Reliability coefficients (r) were calculated for heart rate, systolic blood pressure (SBP), oxygen consumption (VO2 [L/min]), VO2 (mL.kg(-1).min(-1)), respiratory exchange ratio (RER), rate-pressure product (RPP), and oxygen pulse during peak effort testing. The reliability coefficients for all but SBP and RPP data were calculated from the submaximal tests. Results: Heart rate (r=.87), VO(2)peak (L/min) (r=.92), VO(2)peak (mL.kg(-1).min(-1)) (r=.92), and oxygen pulse (r=93) were highly reliable parameters during maximal testing in this population. Submaximal testing produced highly reliable results for (V) over dotO(2) (L/min) (r=.89) and oxygen pulse (r=.85). All cardiopulmonary measures except RER had a reliability coefficient greater than .80 during submaximal testing in this population. Conclusion: Our study provides the first evidence that peak effort treadmill testing provides highly reliable oxygen consumption measures in chronic hemiparetic stroke patients using minimal handrail support. The submaximal tests were at or near the threshold level of reliability for the 2 most important measures of (V) over dotO(2) (L/min) and (V) over dotO(2) (mL.kg(-1).min(-1)) (r=.89, r=.84, respectively), with the remaining measures falling above .70.
引用
收藏
页码:1308 / 1312
页数:5
相关论文
共 29 条
[1]  
[Anonymous], ACSMS GUID EX TEST P
[2]  
[Anonymous], 2000, J STROKE CEREBROVASC, DOI DOI 10.1053/JSCD.2000.16607
[3]  
BARD B, 1963, ARCH PHYS MED REHAB, V44, P368
[4]   MAXIMAL OXYGEN INTAKE AND NOMOGRAPHIC ASSESSMENT OF FUNCTIONAL AEROBIC IMPAIRMENT IN CARDIOVASCULAR DISEASE [J].
BRUCE, RA ;
KUSUMI, F ;
HOSMER, D .
AMERICAN HEART JOURNAL, 1973, 85 (04) :546-562
[5]  
Christman SK, 2000, RES NURS HEALTH, V23, P35
[6]  
Corcoran P J, 1970, Arch Phys Med Rehabil, V51, P69
[7]   The reproducibility of the Bruce protocol exercise test for the determination of aerobic capacity in older women [J].
Fielding, RA ;
Frontera, WR ;
Hughes, VA ;
Fisher, EC ;
Evans, WJ .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1997, 29 (08) :1109-1113
[8]  
Forrester L, 2002, NEUROLOGICAL REHABILITATION, PROCEEDINGS, P263
[9]  
FOSTER VL, 1986, MED SCI SPORT EXER, V18, P425
[10]  
GERSTEN J W, 1971, Scandinavian Journal of Rehabilitation Medicine, V3, P85