Improved determination of Q-factor and resonant frequency by a quadratic curve-fitting method

被引:42
作者
Robinson, MP [1 ]
Clegg, J [1 ]
机构
[1] Univ York, Dept Elect, Phys Laser Grp, York YO10 5DD, N Yorkshire, England
关键词
electromagnetic compatibility (EMC) measurements; interpolation; Q-factor; resonance; resonant frequency;
D O I
10.1109/TEMC.2005.847411
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Q-factor and peak frequency of resonant phenomena give useful information about the propagation and storage of energy in an electronic system and therefore its electromagnetic compatibility performance. However, the calculation of Q by linear interpolation of a discrete frequency response to obtain the half-power bandwidth can give inaccurate results, particularly if the data are noisy or the frequency resolution is low. We describe a more accurate method that makes use of the Lorentzian shape of the resonant peaks and involves fitting a second-order polynomial to the reciprocal power plotted against angular frequency. We demonstrate that this new method requires less than one quarter the number of frequency points as the linear method to give comparable accuracy in Q. The new method also gives comparable accuracy for signal-to-noise ratios that are approximately 8 dB greater. It is also more accurate for determination of peak frequency. Examples are given both from measured frequency responses and from simulated data obtained by the transmission line matrix method.
引用
收藏
页码:399 / 402
页数:4
相关论文
共 7 条
[1]  
Dawson J. F., 2004, IEE Validation of Computational Electromagnetics Seminar, P17, DOI 10.1049/ic:20040105
[2]   APERTURE EXCITATION OF ELECTRICALLY LARGE, LOSSY CAVITIES [J].
HILL, DA ;
MA, MT ;
ONDREJKA, AR ;
RIDDLE, BF ;
CRAWFORD, ML ;
JOHNK, RT .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1994, 36 (03) :169-178
[3]   A reflection coefficient derivation for the Q of a reverberation chamber [J].
Hill, DA .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1996, 38 (04) :591-592
[4]   Precise measurements of the Q factor of dielectric resonators in the transmission mode -: Accounting for noise, crosstalk, delay of uncalibrated lines, coupling loss, and coupling reactance [J].
Leong, K ;
Mazierska, J .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2002, 50 (09) :2115-2127
[5]  
*MATH WORKS INC, 2002, MATL VERS 6 5
[6]  
Press W., 1993, Numerical recipes, V2nd
[7]   A novel method of studying total body water content using a resonant cavity: experiments and numerical simulation [J].
Robinson, MP ;
Clegg, J ;
Stone, DA .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (01) :113-125