Flow injection analysis of glucose based on its inhibition of electrochemiluminescence in a Ru(bpy)3 2+-tripropylamine system

被引:34
作者
Wang, CY [1 ]
Huang, HJ [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 804, Taiwan
关键词
HO2O2; Ru(bpy)(3)(2+)-TPA; glucose oxidase; sol-gel column; electrochemiluminescence; inhibition effect;
D O I
10.1016/j.aca.2003.08.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Based on the linear relationship between concentration of H2O2 and the decrease of electrochemiluminescence (ECL)intensity in a Ru(bpy)(3)(2+)-tripropylamine (TPA) system, procedures for the indirect determination of glucose with a flow injection analysis system were developed. By passing solutions of glucose through a glucose oxidase (GOx)-immobilized sol-gel column and an ECL system of Ru(bpy)(3)(2+) and TPA, glucose can be determined optimally with a detection limit of 1.0 muM in a linear dynamic range of 1.0-200 muM. A repetitive injection of glucose (100 muM) and human serum solutions gave satisfactory reproducibility with R.S.D. of 1.3 (n = 31) and 3.9% (n = 42), respectively. Interference as a result of the presence of ascorbic acid. uric acid or other reducible agents in solution can be corrected by passing sample solutions through another sol-gel column which contained no GOx. From the agreement between the contents of glucose in human serum and soft drink analyzed by the developed method and those obtained by the spectroscopy method-based glucose assay kit and satisfactory recovery of glucose from interferent containing solutions, the feasibility of the developed method for real sample analysis was confirmed. (C) 2003 Published by Elsevier B.V.
引用
收藏
页码:61 / 68
页数:8
相关论文
共 25 条
[1]  
COLLAUDIN AB, 1997, SENSOR ACTUAT B-CHEM, V38, P189
[2]   A NEW NONISOTOPIC DETECTION SYSTEM FOR IMMUNOASSAYS [J].
DEAVER, DR .
NATURE, 1995, 377 (6551) :758-760
[3]   CHEMILUMINESCENCE DETECTION USING REGENERABLE TRIS(2,2'-BIPYRIDYL)RUTHENIUM(II) IMMOBILIZED IN NAFION [J].
DOWNEY, TM ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1992, 64 (03) :261-268
[4]   ENCAPSULATION OF PROTEINS IN TRANSPARENT POROUS SILICATE-GLASSES PREPARED BY THE SOL-GEL METHOD [J].
ELLERBY, LM ;
NISHIDA, CR ;
NISHIDA, F ;
YAMANAKA, SA ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
SCIENCE, 1992, 255 (5048) :1113-1115
[5]   Detection of hydrogen peroxide at mesoporous platinum microelectrodes [J].
Evans, SAG ;
Elliott, JM ;
Andrews, LM ;
Bartlett, PN ;
Doyle, PJ ;
Denuault, G .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1322-1326
[6]   Recent applications of electrogenerated chemiluminescence in chemical analysis [J].
Fähnrich, KA ;
Pravda, M ;
Guilbault, GG .
TALANTA, 2001, 54 (04) :531-559
[7]   Analytical applications of tris(2,2′-bipyridyl)ruthenium(III) as a chemiluminescent reagent [J].
Gerardi, RD ;
Barnett, NW ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) :1-41
[8]   Analysis of tricyclic antidepressants using electrogenerated chemiluminescence [J].
Greenway, GM ;
Dolman, SJL .
ANALYST, 1999, 124 (05) :759-762
[9]   Tris(2,2-bipyridyl)ruthenium (II) chemiluminescence in a microflow injection system for codeine determination [J].
Greenway, GM ;
Nelstrop, LJ ;
Port, SN .
ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) :43-50
[10]   CHEMILUMINESCENT DETECTION OF AMINO-ACIDS USING IN-SITU GENERATED RU(BPY)(3)(3+) [J].
JACKSON, WA ;
BOBBITT, DR .
ANALYTICA CHIMICA ACTA, 1994, 285 (03) :309-320