Stereoselective determination of methadone in serum by HPLC following solid-phase extraction on disk

被引:39
作者
Rudaz, S [1 ]
Veuthey, JL [1 ]
机构
[1] UNIV GENEVA,DEPT PHARMACEUT ANALYT CHEM,CH-1211 GENEVA 4,SWITZERLAND
关键词
methadone; alpha(1)-acid glycoprotein column; chiral analysis; solid-phase extraction; extraction disk; mixed-mode silica bonded phase;
D O I
10.1016/0731-7085(95)01660-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A solid-phase extraction (SPE) technique for methadone has been developed using a mixed-mode solid-phase extraction disk which contains both hydrophobic and cation-exchange functional groups. The SPE technique was used to isolate the drug from the biological matrix and to prepare a cleaner sample prior to stereoselective analysis by HPLC on a silica column with covalently bound alpha(1)-acid glycoprotein (Chiral-AGP) followed by ultraviolet detection at 205 nm. The within-run precision was less than 5% for the complete method over the therapeutic range. The quantification limit was 25 ng ml(-1). The between-run precision was less than 15% at the quantification limit. The between-run precision at other concentrations was less than 8.5% with an accuracy of more than 95%. The mean recovery for R-methadone was 78.5% and the mean recovery for S-methadone was 73.4%. The complete procedure has been validated. This method was successfully used for the analysis of 15 clinical cases.
引用
收藏
页码:1271 / 1279
页数:9
相关论文
共 35 条
[1]   SEPARATION OF DRUG STEREOISOMERS BY THE FORMATION OF BETA-CYCLODEXTRIN INCLUSION COMPLEXES [J].
ARMSTRONG, DW ;
WARD, TJ ;
ARMSTRONG, RD ;
BEESLEY, TE .
SCIENCE, 1986, 232 (4754) :1132-1135
[2]   RETENTION PROCESSES ON ALPHA-1-ACID GLYCOPROTEIN-BONDED STATIONARY PHASE [J].
ARVIDSSON, E ;
JANSSON, SO ;
SCHILL, G .
JOURNAL OF CHROMATOGRAPHY, 1992, 591 (1-2) :55-63
[3]  
BEAUVERIE P, 1994, ANN MED INTERNE, V145, P15
[4]   CHIRAL ANALYSIS OF METHADONE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BECK, O ;
BOREUS, LO ;
LAFOLIE, P ;
JACOBSSON, G .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (01) :198-202
[5]  
BERTSCHY G, 1994, MED HYG, V52, P2178
[6]  
BLEVINS DD, 1994, LC GC EUR, V7, P70
[7]   PITFALLS AND SOLUTIONS IN THE DEVELOPMENT OF A FULLY AUTOMATED SOLID-PHASE EXTRACTION METHOD FOR DRUG SCREENING PURPOSES IN PLASMA AND WHOLE-BLOOD [J].
CHEN, XH ;
FRANKE, JP ;
ENSING, K ;
WIJSBEEK, J ;
DEZEEUW, RA .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (07) :421-426
[8]   DETERMINATION OF BASIC DRUGS EXTRACTED FROM BIOLOGICAL MATRICES BY MEANS OF SOLID-PHASE EXTRACTION AND WIDE-BORE CAPILLARY GAS-CHROMATOGRAPHY WITH NITROGEN PHOSPHORUS DETECTION [J].
CHEN, XH ;
FRANKE, JP ;
WIJSBEEK, J ;
DEZEEUW, RA .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1994, 18 (03) :150-153
[9]   ISOLATION OF ACIDIC, NEUTRAL, AND BASIC DRUGS FROM WHOLE-BLOOD USING A SINGLE MIXED-MODE SOLID-PHASE EXTRACTION COLUMN [J].
CHEN, XH ;
FRANKE, JP ;
WIJSBEEK, J ;
DEZEEUW, RA .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1992, 16 (06) :351-355
[10]   SEMIAUTOMATED SOLID-PHASE EXTRACTION PROCEDURE FOR DRUG SCREENING IN BIOLOGICAL-FLUIDS USING THE ASPEC SYSTEM IN COMBINATION WITH CLEAN SCREEN DAU COLUMNS [J].
CHEN, XH ;
FRANKE, JP ;
ENSING, K ;
WIJSBEEK, J ;
DEZEEUW, RA .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 613 (02) :289-294