Comparison of Cervical Spine Biomechanics After Fixed- and Mobile-Core Artificial Disc Replacement: A Finite Element Analysis

被引:224
作者
Lee, Sang-Hun [1 ]
Im, Yang-Jin [1 ]
Kim, Ki-Tack [1 ]
Kim, Yoon-Hyuk [2 ,3 ]
Park, Won-Man [2 ,3 ]
Kim, Kyungsoo [4 ]
机构
[1] Kyung Hee Univ, Kyung Hee Univ Hosp Gangdong, Spine Ctr, Dept Orthopaed Surg,Sch Med, Seoul, South Korea
[2] Kyung Hee Univ, Dept Mech Engn, ILR Inst, Seoul, South Korea
[3] Kyung Hee Univ, ILR Inst, Ctr Biomech Syst, Seoul, South Korea
[4] Kyonggi Univ, Dept Math, Suwon, South Korea
关键词
biomechanics; cervical artificial disc replacement; finite element analysis; fixed core; mobile core; LEVEL INTRADISCAL PRESSURE; 3-DIMENSIONAL MOTION; FOLLOW-UP; ARTHROPLASTY; ADJACENT; ANTERIOR; FUSION; ROTATION; PROSTHESIS; DISKECTOMY;
D O I
10.1097/BRS.0b013e3181f5cb87
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Study Design. A biomechanical comparison between the intact C2-C7 segments and the C5-C6 segments implanted with two different constrained types (fixed and mobile core) of artificial disc replacement (ADR) using a three-dimensional nonlinear finite element (FE) model. Objective. To analyze the biomechanical changes in subaxial cervical spine after ADR and the differences between fixed- and mobile-core prostheses. Summary of Background Data. Few studies have investigated the changes in kinematics after cervical ADR, particularly in relation to the influence of constrain types. Methods. A FE model of intact C2-C7 segments was developed and validated. Fixed-core (Prodisc-C, Synthes) and mobile-core (Mobi-C, LDR Spine) artificial disc prostheses were integrated at the C5-C6 segment into the validated FE model. All models were subjected to a follower load of 50 N and a moment of 1 Nm in flexion-extension, lateral bending, and axial torsion. The range of segmental motion (ROM), facet joint force, tension on major ligaments, and stress on the polyethylene (PE) cores were analyzed. Results. The ROM in the intact segments after ADR was not significantly different from those of the normal cervical spine model. The ROM in the implanted segment (C5-C6) increased during flexion (19% for fixed and 33% for mobile core), extension (48% for fixed and 56% for mobile core), lateral bending (28% for fixed and 35% for mobile core) and axial torsion (45% for fixed and 105% for mobile core). The facet joint force increased by 210% in both fixed and mobile core models during extension and the tension increased (range, 66%-166%) in all ligaments during flexion. The peak stress on a PE core was greater than the yield stress (51 MPa for fixed and 36 MPa for mobile core). Conclusion. The results of our study presented an increase in ROM, facet joint force, and ligament tension at the ADR segments. The mobile-core model showed a higher increase in segmental motion, facet force, and ligament tension, but lower stress on the PE core than the fixed-core model.
引用
收藏
页码:700 / 708
页数:9
相关论文
共 51 条
[1]
A biomechanical study of artificial cervical discs using computer simulation [J].
Ahn, Hyung Soo ;
DiAngelo, Denis J. .
SPINE, 2008, 33 (08) :883-892
[2]
Comparison of adverse events between the Bryan artificial cervical disc and anterior cervical arthrodesis [J].
Anderson, Paul A. ;
Sasso, Rick C. ;
Riew, K. Daniel .
SPINE, 2008, 33 (12) :1305-1312
[3]
Early results after ProDisc-C cervical disc replacement [J].
Bertagnoli, R ;
Yue, JJ ;
Pfeiffer, F ;
Fenk-Mayer, A ;
Lawrence, JP ;
Kershaw, T ;
Nanieva, R .
JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (04) :403-410
[4]
Changes in adjacent-level disc pressure and facet joint force after cervical arthroplasty compared with cervical discectomy and fusion [J].
Chang, Ung-Kyu ;
Kim, Daniel H. ;
Lee, Max C. ;
Willenberg, Rafer ;
Kim, Se-Hoon ;
Lim, Jesse .
JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (01) :33-39
[5]
Biomechanical comparison between lumbar disc arthroplasty and fusion [J].
Chen, Shih-Hao ;
Zhong, Zheng-Cheng ;
Chen, Chen-Sheng ;
Chen, Wen-Jer ;
Hung, Chinghua .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (02) :244-253
[6]
Uncinate processes and Luschka joints influence the biomechanics of the cervical spine: Quantification using a finite element model of the C5-C6 segment [J].
Clausen, JD ;
Goel, VK ;
Traynelis, VC ;
Scifert, J .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (03) :342-347
[7]
Biomechanical evaluation of total disc replacement arthroplasty:: An in vitro human cadaveric model [J].
Cunningham, BW ;
Gordon, JD ;
Dmitriev, AE ;
Hu, NB ;
McAfee, PC .
SPINE, 2003, 28 (20) :S110-S117
[8]
General principles of total disc replacement arthroplasty - Seventeen cases in a nonhuman primate model [J].
Cunningham, BW ;
Dmitriev, AE ;
Hu, NB ;
McAfee, PC .
SPINE, 2003, 28 (20) :S118-S124
[9]
DiAngelo Denis J, 2004, Neurosurg Focus, V17, pE4
[10]
Adjacent level intradiscal pressure and segmental kinematics following a cervical total disc arthroplasty -: An In Vitro human cadaveric model [J].
Dmitriev, AE ;
Cunningham, BW ;
Hu, NB ;
Sell, G ;
Vigna, F ;
McAfee, PC .
SPINE, 2005, 30 (10) :1165-1172