Use of a test-bed to study the performance of micro gas turbines for cogeneration applications

被引:38
作者
Caresana, Flavio [1 ]
Comodi, Gabriele [1 ]
Pelagalli, Leonardo [1 ]
Renzi, Massimiliano [2 ]
Vagni, Sandro [3 ]
机构
[1] Univ Politecn Marche, Dipartimento Energet, I-60131 Ancona, Italy
[2] S TRA TE GIE Srl, I-60131 Ancona, Italy
[3] Univ E Campus, I-22060 Novedrate, Italy
关键词
Micro gas turbine; Cogeneration; Test-bed; Thermal recovery; Electrical performance; Primary energy saving; TRIGENERATION; MICROTURBINES; BENEFITS; SYSTEM;
D O I
10.1016/j.applthermaleng.2011.07.016
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents the experimental results of a test-bed developed to analyze a 100 kW cogeneration micro gas turbine (MGT). Its main feature, flexibility, allows MGT testing in nearly all the conditions that final use may entail, in particular simulation of operating conditions and thermal loads in broadly different electrical power, flow rate and temperature conditions of the cogeneration circuit. The MGT and its operating modes are described and the test-bed design philosophy is outlined. Finally the methods applied to test the cogeneration plant's performance are described and the experimental results in terms of power, efficiency, primary energy saving (PES) index and emissions are reported. In the tests electrical power ranged between 40 and 100 kW; electrical efficiency reached similar to 29% in the 80-100 kW range. Analysis of the performance of the recovery heat exchanger at different values of inlet and outlet water temperature and flow rate showed that the maximum thermal power recovered was 160 kW and the maximum PES index was about 24%. With regard to the main pollutants at the exhaust, NO concentrations were <6 ppmv in the whole MGT working range, while CO concentrations increased substantially at low electrical power values, starting from around 10 ppmv at nominal load. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3552 / 3558
页数:7
相关论文
共 21 条
[1]  
BLASCO M, 2006, BIOPR PROJ WORKSH TA
[2]  
BRANDON R, 2006, 6 ANN MICR APPL WORK
[3]   Performance analysis of combined microgas turbines and gas fired water/LiBr absorption chillers with post-combustion [J].
Bruno, JC ;
Valero, A ;
Coronas, A .
APPLIED THERMAL ENGINEERING, 2005, 25 (01) :87-99
[4]   Microturbines and trigeneration: Optimization strategies and multiple engine configuration effects [J].
Campanari, S ;
Boncompagni, L ;
Macchi, E .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2004, 126 (01) :92-101
[5]  
CARESANA F, 2008, P ASME TURB EXP 2008
[6]   Integration of absorption cooling systems into micro gas turbine trigeneration systems using biogas: Case study of a sewage treatment plant [J].
Caries Bruno, Joan ;
Ortega-Lopez, Victor ;
Coronas, Alberto .
APPLIED ENERGY, 2009, 86 (06) :837-847
[7]   Experimentation on a cogenerative system based on a microturbine [J].
Colombo, Luigi P. M. ;
Armanasco, Fabio ;
Perego, Omar .
APPLIED THERMAL ENGINEERING, 2007, 27 (04) :705-711
[8]  
FAIRCHILD PD, 2001, ADV ENERGY SYSTEMS D, V41, P179
[9]   Potential energy benefits of integrated refrigeration system with microturbine and absorption chiller [J].
Hwang, YH .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (08) :816-829
[10]  
*INT EN AG, 2002, IEA DISTR GEN LIB EL