Micropollutants migration from ion-exchange resins into water

被引:9
作者
Botta, D [1 ]
Mantica, E [1 ]
机构
[1] Politecn Milan, Dept Chem Engn & Ind Chem, I-20133 Milan, Italy
关键词
GC; CC-MS; ion exchangers; potable water contamination;
D O I
10.1016/S0043-1354(98)00299-1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Water samples collected at different stages of a demineralization process were examined after closed loop stripping and analysed by GC-FID and CC-MS. The results showed a contamination arising from the contact with ion-exchange resins. The quantity and the type of pollutants were different depending upon the resin bed, cationic or anionic exchanger, but all the examined samples exceeded the limits set according to the normative for the human consumption water for various classes of compounds: Alkylparaffns, alkylbenzenes, alkyltoluenes, aromatic chloro-, and bromoderivatives. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1054 / 1064
页数:11
相关论文
共 8 条
[1]   BEADED POLYMER SUPPORTS AND GELS .2. PHYSICOCHEMICAL CRITERIA AND FUNCTIONALIZATION [J].
ARSHADY, R .
JOURNAL OF CHROMATOGRAPHY, 1991, 586 (02) :199-219
[2]   BEADED POLYMER SUPPORTS AND GELS .1. MANUFACTURING TECHNIQUES [J].
ARSHADY, R .
JOURNAL OF CHROMATOGRAPHY, 1991, 586 (02) :181-197
[3]  
*DIN, 1987, DIN54411
[4]  
KLINGSBERG A, 1988, ENCY POLYM SCI ENG, V14, P299
[5]  
*MIN AFF SOC, 1987, DGSPGE1 MIN AFF SOC
[6]  
*MIN SAN DGSIP, 1978, 102 DGSIP MIN SAN, P1260
[7]  
PLATT AE, 1983, KIRKOTHMER ENCY CHEM, V21, P801
[8]  
1985, BUNDESGESUNDHEITSBLA, V28, P24