Determination of 14 benzodiazepines and hydroxy metabolites, zaleplon and zolpidem as tert-butyldimethylsilyl derivatives compared with other common silylating reagents in whole blood by gas chromatography-mass spectrometry

被引:66
作者
Gunnar, T
Ariniemi, K
Lillsunde, P
机构
[1] Natl Publ Hlth Inst, Drug Res Unit, Helsinki 00300, Finland
[2] Aalto Univ, Inorgan & Analyt Chem Lab, Espoo 02015, Finland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2005年 / 818卷 / 02期
关键词
GC-MS; silylation; enzodiazepines; zolpidem; zaleplon;
D O I
10.1016/j.jchromb.2004.12.032
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The most common commercially available silylating reagents, N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA), N,O-bis-(trimethylsilyl)trifluoroacetamide + 1% trimethylchlorosilane (BSTFA + 1% TMCS) and N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA) were evaluated to achieve optimal derivatization conditions for analyzing various benzodiazepines based on gas chromatography-electron impact ionization-mass spectrometry (GC-EI-MS). Sensitivity, repeatability, retention times and stability of the derivatives, as well as specificity of mass fragmentation, were studied in detail. Also other parameters affecting the derivatization chemistry of benzodiazepines are discussed. tert-Butyldimethylsilyl (TBDMS) derivatives proved to be more stable, reproducible and sensitive than corresponding trimethylsilyl (TMS) derivatives for the GC-EI-MS analysis of benzodiazepines. Based on the TBDMS derivatives, a rapid, reliable, sensitive and quantitative GC-MS method was developed for the determination of 14 benzodiazepines and two hydroxy metabolites, as well as two non-benzodiazepine hypnotic agents, zolpidem and zaleplon, using 500 mu l of whole blood. The method was completely validated in terms of accuracy, intra- and interday precision, limit of detection (LOD), limit of quantitation (LOQ), linearity, selectivity and extraction efficiency; these were all within the required limits, except for the accuracy of nitrazepam at a medium concentration level. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:175 / 189
页数:15
相关论文
共 47 条
[1]  
BASELT C, 2001, DRUG EFFECTS PSYCHOM
[2]   Determination of flunitrazepam and its metabolites in blood by high-performance liquid chromatography atmospheric pressure chemical ionization mass spectrometry [J].
Bogusz, MJ ;
Maier, RD ;
Krüger, KD ;
Früchtnicht, W .
JOURNAL OF CHROMATOGRAPHY B, 1998, 713 (02) :361-369
[3]   Simultaneous determination of fifteen low-dosed benzodiazepines in human urine by solid-phase extraction and gas chromatography-mass spectrometry [J].
Borrey, D ;
Meyer, E ;
Lambert, W ;
Van Peteghem, C ;
De Leenheer, AP .
JOURNAL OF CHROMATOGRAPHY B, 2001, 765 (02) :187-197
[4]   Testing for benzodiazepine inebriation-relationship between benzodiazepine concentration and simple clinical tests for impairment in a sample of drugged drivers [J].
Bramness, JG ;
Skurtveit, S ;
Morland, J .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 2003, 59 (8-9) :593-601
[5]   QUANTITATION OF FLURAZEPAM AND 3 METABOLITES BY ELECTRON-CAPTURE GAS-LIQUID CHROMATOGRAPHY [J].
BURSTEIN, ES ;
FRIEDMAN, H ;
GREENBLATT, DJ ;
LOCNISKAR, A ;
OCHS, HR .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1988, 12 (03) :122-125
[6]   Validated method for the therapeutic drug monitoring of flunitrazepam in human serum using liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry with an ion trap detector [J].
Darius, J ;
Banditt, P .
JOURNAL OF CHROMATOGRAPHY B, 2000, 738 (02) :437-441
[7]   Methods for the measurement of benzodiazepines in biological samples [J].
Drummer, OH .
JOURNAL OF CHROMATOGRAPHY B, 1998, 713 (01) :201-225
[8]   High-performance liquid chromatographic method for the determination of benzodiazepines in plasma or serum using the column-switching technique [J].
El Mahjoub, A ;
Staub, C .
JOURNAL OF CHROMATOGRAPHY B, 2000, 742 (02) :381-390
[9]   Simultaneous determination of benzodiazepines in whole blood or serum by HPLC/DAD with a semi-micro column [J].
El Mahjoub, A ;
Staub, C .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (2-3) :447-458
[10]  
Evershed R.P., 1993, HDB DERIVATIVES CHRO, P51