Theoretical and experimental study of a direct contact thermal screw dryer for biomass residues

被引:12
作者
Al-Kassir, A
Gañan, J
Tinaut, FV
机构
[1] Univ Extremadura, Dept Energy & Chem Engn, E-06071 Badajoz, Spain
[2] Univ Valladolid, Dept Energy Engn & Fluid Mech, E-47011 Valladolid, Spain
关键词
thermal; calculation; experimental; dryer; biomass; washed grape pomance;
D O I
10.1016/j.applthermaleng.2005.02.006
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present study a one-dimensional model has been developed for the calculation and design of a direct contact thermal screw dryer for biomass residues. The model input data are inlet temperatures and the flow rates of gas and biomass (washed grape pomance). An experimental facility has been developed in order to measure the temperature inside the dryer along time. The results obtained indicated that Frossling correlation used for the development of the model provided a satisfactory fitting of the experimental data. An optimal dryer length of approximately 3 m has been calculated for an inner diameter of 0.22 m. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2816 / 2826
页数:11
相关论文
共 8 条
[1]
ALKASSIR AR, 2001, ENERGY DEV SUMM INT
[2]
Drying technologies for an integrated gasification bio-energy plant [J].
Brammer, JG ;
Bridgwater, AV .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 1999, 3 (04) :243-289
[3]
CHAPMAN JA, 1990, HEAT TRANSFER
[4]
KNEULE F, 1984, EL SECADO URMO
[5]
A thermal model for prediction of the Nusselt number in a pipe with chaotic flow [J].
Lemenand, T ;
Peerhossaini, H .
APPLIED THERMAL ENGINEERING, 2002, 22 (15) :1717-1730
[6]
LLEIDA JMP, 1991, MADERAY SECADO IND
[7]
Raschieri J. Pistono, 1955, DESECACION PRODUCTOS
[8]
Analytical prediction of friction factors and Nusselt numbers of turbulent forced convection in rod bundles with smooth and rough surfaces [J].
Su, J ;
Freire, APS .
NUCLEAR ENGINEERING AND DESIGN, 2002, 217 (1-2) :111-127