Revision of cemented hip arthroplasty using a hydroxyapatite-ceramic-coated femoral component

被引:20
作者
Raman, R [1 ]
Kamath, RP [1 ]
Parikh, A [1 ]
Angus, PD [1 ]
机构
[1] Dewsbury Hosp, Mid Yorkshire Hosp NHS Trust, Dewsbury WF13 4HS, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2005年 / 87B卷 / 08期
关键词
D O I
10.1302/0301-620X.87B8.16161
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We report the clinical and radiological outcome of 86 revisions of cemented hip arthroplasties using JRI-Furlong hydroxyapatite-ceramic-coated acetabular and femoral components. The acetabular component was revised in 62 hips and the femoral component in all hips. The mean follow-up was 12.6 years and no patient was lost to follow-up. The mean age of the patients was 71.2 years. The mean Harris hip and Oxford scores were 82 (59 to 96) and 23.4 (14 to 40), respectively. The mean Charnley modification of the Merle d'Aubigne and Postel score was 5 (3 to 6) for pain, 4.9 (3 to 6) for movement and 4.4 (3 to 6) for mobility. Migration of the acetabular component was seen in two hips and the mean acetabular inclination was 42.6 degrees. The mean linear polyethylene wear was 0.05 mm/ year. The mean subsidence of the femoral component was 1.9 mm and stress shielding was seen in 23 (28%) with bony ingrowth in 76 (94%). Heterotopic ossification was seen in 12 hips (15%). There were three re-revisions, two for deep sepsis and one for recurrent dislocation and there were no re-revisions for aseptic loosening. The mean EuroQol EQ-5D description scores and health thermometer scores were 0.69 (0.51 to 0.89) and 79 (54 to 95), respectively. With an end-point of definite or probable loosening, the probability of survival at 12 years was 93.9% and 95.6% for the acetabular and femoral components, respectively. Overall survival at 12 years, with removal or further revision of either component for any reason as the end-point, was 92.3%. Our study supports the continued use of this arthroplasty and documents the durability of hydroxyapatite-ceramic-coated components.
引用
收藏
页码:1061 / 1067
页数:7
相关论文
共 76 条
[1]  
AMSTUTZ HC, 1982, CLIN ORTHOP RELAT R, V170, P21
[2]  
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[3]  
Bargar W L, 1993, J Arthroplasty, V8, P245, DOI 10.1016/S0883-5403(06)80085-9
[4]   TESTING THE VALIDITY OF THE EUROQOL AND COMPARING IT WITH THE SF-36 HEALTH SURVEY QUESTIONNAIRE [J].
BRAZIER, J ;
JONES, N ;
KIND, P .
QUALITY OF LIFE RESEARCH, 1993, 2 (03) :169-180
[5]   Using the SF-36 and Euroqol on an elderly population [J].
Brazier, JE ;
Walters, SJ ;
Nicholl, JP ;
Kohler, B .
QUALITY OF LIFE RESEARCH, 1996, 5 (02) :195-204
[6]   ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[7]   EuroQol: The current state of play [J].
Brooks, R .
HEALTH POLICY, 1996, 37 (01) :53-72
[8]  
Brown Thomas E, 2002, J Am Acad Orthop Surg, V10, P385
[9]   Cementless revision of total hip arthroplasty using the anatomic porous replacement revision prosthesis [J].
Buoncristiani, AM ;
Dorr, LD ;
Johnson, C ;
Wan, Z .
JOURNAL OF ARTHROPLASTY, 1997, 12 (04) :403-415
[10]   RESULTS OF REVISION FOR MECHANICAL FAILURE AFTER CEMENTED TOTAL HIP-REPLACEMENT, 1979 TO 1982 - A 2 TO 5-YEAR FOLLOW-UP [J].
CALLAGHAN, JJ ;
SALVATI, EA ;
PELLICCI, PM ;
WILSON, PD ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1074-1085