Bronchial wall thickness: Appropriate window settings for thin-section CT and radiologic-anatomic correlation

被引:68
作者
Bankier, AA
Fleischmann, D
Mallek, R
Windisch, A
Winkelbauer, FW
Kontrus, M
Havelec, L
Herold, CJ
Hubsch, P
机构
[1] UNIV VIENNA, INST ANAT, A-1090 VIENNA, AUSTRIA
[2] UNIV VIENNA, INST MED STAT, A-1090 VIENNA, AUSTRIA
关键词
bronchi; diseases; computed tomography (CT); technology; thin-section; lung; CT;
D O I
10.1148/radiology.199.3.8638013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To analyze the influence of computed tomographic (CT) window settings on bronchial wall thickness and to define appropriate window settings for its evaluation. MATERIALS AND METHODS: Three inflation-fixed lungs were scanned with a section thickness of 1.5 mm by using a high-spatial-frequency algorithm. Wall thickness in 10 bronchial specimens was measured with planimetry. Window centers were altered in a range of -200 to -900 HU and window widths in a range of 400-1,500 HU. Relative and absolute differences between CT and planimetric values were calculated. CT and planimetric measures were correlated. Inter- and intraobserver variabilities were determined. RESULTS: Window widths less than 1,000 HU resulted in a substantial overestimation of bronchial wall thickness, whereas widths greater than 1,400 HU resulted in an underestimation of bronchial wall thickness. There was no interaction between ''width'' and ''center'' regarding their influence on bronchial walls (F = 0.23; P = .99). Correlation between CT and planimetry was statistically significant (r = .85; P = .0001). Differences between the two observers were not statistically significant; results of the measurements of the two observers correlated well (r = .97; P = .001). CONCLUSION: Bronchial wall thickness on thin-section CT scans should be evaluated with window centers between -250 and -700 HU and with window widths greater than 1,000 HU. Other window settings, notably window widths less than 1,000 HU, can lead to substantial artificial thickening of bronchial walls.
引用
收藏
页码:831 / 836
页数:6
相关论文
共 28 条
  • [1] FACTORS AFFECTING THE MEASUREMENT OF SIZE AND CT-NUMBER IN COMPUTED-TOMOGRAPHY
    BAXTER, BS
    SORENSON, JA
    [J]. INVESTIGATIVE RADIOLOGY, 1981, 16 (04) : 337 - 341
  • [2] CO CS, 1986, J COMPUT ASSIST TOMO, V10, P424
  • [3] COSIO MG, 1980, AM REV RESPIR DIS, V122, P265
  • [4] THE REPRODUCIBILITY OF BRONCHIAL CIRCUMFERENCE MEASUREMENTS USING COMPUTED-TOMOGRAPHY
    DESAI, SR
    WELLS, AU
    CHEAH, FK
    COLE, PJ
    HANSELL, DM
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (795) : 257 - 262
  • [5] WHOLE LUNG SECTIONS FOR COMPUTED TOMOGRAPHIC PATHOLOGICAL CORRELATIONS - MODIFIED GOUGH-WENTWORTH TECHNIQUE
    GEVENOIS, PA
    KOOB, MC
    JACOBOVITZ, D
    DEVUYST, P
    YERNAULT, JC
    STRUYVEN, J
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 (03) : 242 - 246
  • [6] BRONCHIECTASIS - ASSESSMENT BY THIN-SECTION CT
    GRENIER, P
    MAURICE, F
    MUSSET, D
    MENU, Y
    NAHUM, H
    [J]. RADIOLOGY, 1986, 161 (01) : 95 - 99
  • [7] Grenier P, 1993, J Thorac Imaging, V8, P213, DOI 10.1097/00005382-199322000-00006
  • [8] THE EFFECT ON APPARENT SIZE OF SIMULATED PULMONARY NODULES OF USING 3 STANDARD CT WINDOW SETTINGS
    HARRIS, KM
    ADAMS, H
    LLOYD, DCF
    HARVEY, DJ
    [J]. CLINICAL RADIOLOGY, 1993, 47 (04) : 241 - 244
  • [9] HIGH-RESOLUTION COMPUTED-TOMOGRAPHY OF INFLATION-FIXED LUNGS - PATHOLOGICAL-RADIOLOGIC CORRELATION OF CENTRILOBULAR EMPHYSEMA
    HRUBAN, RH
    MEZIANE, MA
    ZERHOUNI, EA
    KHOURI, NF
    FISHMAN, EK
    WHEELER, PS
    DUMLER, JS
    HUTCHINS, GM
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 136 (04): : 935 - 940
  • [10] KOEHLER PR, 1979, RADIOLOGY, V130, P189