Development of a method for measuring single-pass bioaerosol removal efficiencies of a room air cleaner

被引:24
作者
Foarde, KK
Hanley, JT
Ensor, DS
Roessler, P
机构
[1] Res Triangle Inst, Ctr Engn & Environm Technol, Res Triangle Pk, NC 27709 USA
[2] Amway Corp, Ada, MI 49355 USA
关键词
D O I
10.1080/027868299304804
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper presents the development of a method to measure single-pass microbial particle reduction by a room air cleaner having a built-in blower, The method used a Collison nebulizer to generate bioaerosol challenge for injection into a 14 m(3)/min airflow duct. Bioaerosol samplers (impactors) were used to obtain upstream and downstream samples. The success of the method required ensuring the survivability and culturability of the organisms, the selection of appropriate test organisms for this application, the implementation of the necessary control tests, the development of good sampling protocols, and the use of nonbiological aerosol tests for comparisons and Quality Assurance/Quality Control (QA/QC) checks, A series of filtration efficiency tests was performed on only the filter elements of the air cleaner. The tests were conducted with two Gram-positive bacteria, Bacillus subtilis and Staphylococcus epidermidis, and, for comparison and QA/QC purposes, two nonbiological challenge aerosols, The biological data compared well with the nonbiological particulate test results, and both results were highly reproducible, Next, a series of filtration efficiency tests was performed on the entire air cleaner assembly using five different biological aerosols (two bacteria, two fungi, and a virus). For these tests the air cleaner was mounted in a test duct with the built-in fan operating and the flows balanced to simulate free-standing operation. The results of these tests were also highly repeatable and correlated well with the nonbiological test results.
引用
收藏
页码:223 / 234
页数:12
相关论文
共 9 条
[1]  
*AM C GOV IND HYG, 1989, ACGIH GUID ASS BIOAE
[2]  
BRACHMAN PS, 1964, SCIENCE, V144, P1295
[3]   SYSTEM-DESIGN AND TEST METHOD FOR MEASURING RESPIRATOR FILTER EFFICIENCY USING MYCOBACTERIUM AEROSOLS [J].
BROSSEAU, LM ;
CHEN, SK ;
VESLEY, D ;
VINCENT, JH .
JOURNAL OF AEROSOL SCIENCE, 1994, 25 (08) :1567-1577
[4]   LOSS OF INFECTIVITY ON DRYING VARIOUS VIRUSES [J].
BUCKLAND, FE ;
TYRRELL, DAJ .
NATURE, 1962, 195 (4846) :1063-+
[5]   FRACTIONAL AEROSOL FILTRATION EFFICIENCY OF IN-DUCT VENTILATION AIR CLEANERS [J].
HANLEY, JT ;
ENSOR, DS ;
SMITH, DD ;
SPARKS, LE .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (03) :169-178
[6]  
HANLEY JT, 1995, ASHRAE T 1, V3842, pV101
[7]  
KNIGHT V, 1973, VIRAL MYCOPLASMAL IN
[8]  
MACHER JM, 1989, AM IND HYG ASSOC J, V50, P561, DOI 10.1080/15298668991375164
[9]   Collection efficiencies of coarse and fine dust filter media for airborne biological particles [J].
Maus, R ;
Umhauer, H .
JOURNAL OF AEROSOL SCIENCE, 1997, 28 (03) :401-415