Toxicity-directed fractionation of tannery wastewater using solid-phase extraction and luminescence inhibition in microtiter plates

被引:20
作者
Fiehn, O [1 ]
Vigelahn, L [1 ]
Kalnowski, G [1 ]
Reemtsma, T [1 ]
Jekel, M [1 ]
机构
[1] Tech Univ Berlin, FG Wasserreinhaltung, D-10623 Berlin, Germany
来源
ACTA HYDROCHIMICA ET HYDROBIOLOGICA | 1997年 / 25卷 / 01期
关键词
wastewater; toxicity; solid-phase extraction; polar organics; luminescence inhibition;
D O I
10.1002/aheh.19970250103
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A four-step solid-phase extraction (SPE) method is presented for toxicity-directed fractionation of industrial wastewater. This fractionation procedure serves as a key step for identifying unknown organic toxicants in complex samples. Toxicity was determined as luminescence inhibition of Vibrio fischeri using microtiter plates. This method was compared to standard tests in glass cuvettes using both 37 standard chemicals and 24 wastewater fractions with EC50 values covering five orders of magnitude. Results of both methods correlated well. 22 tannery wastewater samples were sequentially extracted using C(18)e and polystyrene-divinylbenzene phases in combination with pH-changes. Final solid-phase filtrates showed low inhibition, so toxicity of inorganics could be neglected. Using 1/EC50 values, the SPE eluates showed clearly different toxicity patterns. Even in eluates of the fourth extraction step, high toxic effects could be observed. In several cases, luminescence inhibition was increasing at the anaerobic treatment step compared to the corresponding untreated samples. After aerobic treatment, toxicity of most wastewater fractions was greatly diminished. HPLC/DAD analyses of the wastewater fractions showed a fair separation concerning compound polarity. However, the samples were still too complex to identify single compounds responsible for the detected toxicity. Therefore, a further clean-up step accompanied with toxicity testing is needed.
引用
收藏
页码:11 / 16
页数:6
相关论文
共 28 条
[1]  
AMATO JR, 1992, ENVIRON TOXICOL CHEM, V11, P209, DOI 10.1897/1552-8618(1992)11[209:AEOTIO]2.0.CO
[2]  
2
[3]   IDENTIFICATION OF NONPOLAR TOXICANTS IN EFFLUENTS USING TOXICITY-BASED FRACTIONATION WITH GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BURKHARD, LP ;
DURHAN, EJ ;
LUKASEWYCZ, MT .
ANALYTICAL CHEMISTRY, 1991, 63 (03) :277-283
[4]   MECHANISM AND PREDICTION OF NONSPECIFIC TOXICITY TO FISH USING BIOCONCENTRATION CHARACTERISTICS [J].
CONNELL, D ;
MARKWELL, R .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 1992, 24 (03) :247-265
[5]  
Durhan E. J., 1993, Methods for aquatic toxicity identification evaluations: Phase II toxicity identification procedures for samples exhibiting acute and chronic toxicity
[6]  
ELSASSER W, 1992, ACTA HYDROCH HYDROB, V20, P82
[7]   Comparison of sorbents using semipolar to highly hydrophilic compounds for a sequential solid-phase extraction procedure of industrial wastewaters [J].
Fiehn, O ;
Jekel, M .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3083-3089
[8]  
FIEHN O, 1996, UNPUB J CHROMATOGR
[9]   MONITORING RESPONSE OF XAD-CONCENTRATED WATER IN THE RHINE DELTA - A MAJOR PART OF THE TOXIC COMPOUNDS REMAINS UNIDENTIFIED [J].
HENDRIKS, AJ ;
MAASDIEPEVEEN, JL ;
NOORDSIJ, A ;
VANDERGAAG, MA .
WATER RESEARCH, 1994, 28 (03) :581-598
[10]   AUTOMATIC-MEASUREMENT OF PESTICIDES IN DRINKING-WATER USING ONLINE SOLID-PHASE EXTRACTION, HPLC AND CHEMOMETRY [J].
HUEN, JM ;
GILLARD, R ;
MAYER, AG ;
BALTENSPERGER, B ;
KERN, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (8-9) :606-614