Automated detection of diabetic retinopathy in digital retinal images: a tool for diabetic retinopathy screening

被引:196
作者
Usher, D
Dumskyj, M
Himaga, M
Williamson, TH [1 ]
Nussey, S
Boyce, J
机构
[1] St Thomas Hosp, Dept Ophthalmol, London SE1 7EH, England
[2] Kings Coll London, Dept Phys, London WC2R 2LS, England
[3] Univ London St Georges Hosp, Sch Med, Dept Oncol Gastroenterol Endocrinol & Metab, London SW17 0RE, England
[4] Royal Free Hosp, Dept Endocrinol, London NW3 2QG, England
关键词
diabetic retinopathy; screening; image analysis; neural network;
D O I
10.1046/j.1464-5491.2003.01085.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To develop a system to detect automatically features of diabetic retinopathy in colour digital retinal images and to evaluate its potential in diabetic retinopathy screening. Methods Macular centred 45degrees colour retinal images from 1273 patients in an inner city diabetic retinopathy screening programme. A system was used involving pre-processing to standardize colour and enhance contrast, segmentation to reveal possible lesions and classification of lesions using an artificial neural network. The system was trained using a subset of images from 500 patients and evaluated by comparing its performance with a human grader on a test set of images from 773 patients. Results Maximum sensitivity for detection of any retinopathy on a per patient basis was 95.1%, accompanied by specificity of 46.3%. Specificity could be increased as far as 78.9% but was accompanied by a fall in sensitivity to 70.8%. At a setting with 94.8% sensitivity and 52.8% specificity, no cases of sight-threatening retinopathy were missed (retinopathy warranting immediate ophthalmology referral or re-examination sooner than 1 year by National Institute for Clinical Excellence criteria). If the system was implemented at 94.8% sensitivity setting over half the images with no retinopathy would be correctly identified, reducing the need for a human grader to examine images in 1/3 of patients. Conclusion This system could be used when screening for diabetic retinopathy. At 94.8% sensitivity setting the number of normal images requiring examination by a human grader could be halved.
引用
收藏
页码:84 / 90
页数:7
相关论文
共 35 条
[1]  
[Anonymous], 1978, Ophthalmology, V85, P82
[2]   An economic analysis of screening for diabetic retinopathy [J].
Bjorvig, S ;
Johansen, MA ;
Fossen, K .
JOURNAL OF TELEMEDICINE AND TELECARE, 2002, 8 (01) :32-35
[3]   National screening programme for diabetic retinopathy - Digital image may be better for screening [J].
Clements, C .
BMJ-BRITISH MEDICAL JOURNAL, 2002, 324 (7341) :849-849
[4]   A fully automated comparative microaneurysm digital detection system [J].
Cree, MJ ;
Olson, JA ;
McHardy, KC ;
Sharp, PF ;
Forrester, JV .
EYE, 1997, 11 (5) :622-628
[5]  
Early Treatment Diabetic Retinopathy Study Res Grp, 1991, OPHTHALMOLOGY, V98, P766
[6]   Screening for diabetic retinopathy using computer based image analysis and statistical classification [J].
Ege, BM ;
Hejlesen, OK ;
Larsen, OV ;
Moller, K ;
Jennings, B ;
Kerr, D ;
Cavan, DA .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2000, 62 (03) :165-175
[7]  
EVANS J, 1996, HLTH TRENDS, V28, P5
[8]   Automatic detection of diabetic retinopathy using an artificial neural network: A screening tool [J].
Gardner, GG ;
Keating, D ;
Williamson, TH ;
Elliott, AT .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (11) :940-944
[9]  
Haykin S., 1999, Neural Networks: A Comprehensive Foundation, V2nd ed
[10]   Colour slides or digital photography in diabetes screening - a comparison [J].
Henricsson, M ;
Karlsson, C ;
Ekholm, L ;
Kaikkonen, P ;
Sellman, A ;
Steffert, E ;
Tyrberg, M .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2000, 78 (02) :164-168