Plateletpheresis concentrates produced with the COMTEC cell separator:: the French experience

被引:9
作者
Coffe, C
Benguella, M
Domy, M
Cottier, D
Guignier, F
N'gondara, JP
Carrère, A
Masse, M
Naegelen, C
Biggio, B
Tiberghien, P
Hervè, P
Bouzgarrou, R
Maurel, JP
Vezon, G
Vidal, M
Quainon, F
Benamara, A
Lamy, B
Beaumont, JL
Bierling, P
Gondrexon, G
Schooneman, F
Janot, C
Villard, F
Huart, JJ
机构
[1] EFS Bourgogne Franche Comte, F-21078 Dijon, France
[2] EFS Aquitaine Limousin, F-33035 Bordeaux, France
[3] EFS Auvergne Loire, F-63003 Clermont Ferrand, France
[4] EFS Auvergne Loire, F-94000 Creteil, France
[5] EFS Ile France, F-94000 Creteil, France
[6] EFS Lorraine Champagne, F-54511 Vandoeuvre Les Nancy, France
[7] EFS Nord France, F-59012 Lille, France
关键词
cell separator; donor apheresis; leucocyte depletion; plateletpheresis;
D O I
10.1016/S1473-0502(01)00089-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The latest generation of cell separators such as Trima (Gambro), Amicus (Baxter) and AS-TEC 204 (Fresenius), allow the collection of leucocyte-reduced platelet concentrates without secondary filtration. Fresenius has recently developed the COMTEC cell separator whose performance has been evaluated by several teams in France. This new cell separator is an improved version of the Fresenius AS-TEC 204 cell separator, designed to allow more efficient platelet collections. This study reports on the experience of six French teams (from Bordeaux, Clermont-Ferrand, Creteil, Dijon, Lille and Nancy) who obtained 696 leucocyte-reduced plateletpheresis concentrates in the course of collection using the new Fresenius COMTEC cell separator. All healthy volunteer donors fulfilled French selection criteria for platelet apheresis. Donors were eligible if they had suitable venous accesses, if their bodyweight was (*)50 kg and if their pre-apheresis platelet count was > 150 x 10(9) l(-1). Between 4606 and 5229 ml of blood were processed. The mean volume of the platelet concentrates was between 439 and 493 ml (mean 460 +/- 63 ml). The platelet yield was of the order of 5.18 +/- 1.02 x 10(11) with only one platelet concentrate below the norm of 2 x 10(11) platelets (0.91 x 10(11)). No plausible explanation for this was found. The residual leucocyte levels conform to current norms. The platelet concentrates contained less than 1 x 10(6) leucocytes, per concentrate (mean 0.233 +/- 0.150 x 10(6) leucocytes) in more than 97% of the components produced with > 95% statistical confidence. The efficacy of the cell separator (52.44 +/- 7.35%) is comparable to that of other separators. The Fresenius COMTEC cell separator makes, it possible to obtain leucocyte-reduced platelet concentrates which comply with current standards both in terms of platelet content and residual leucocyte level. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:67 / 72
页数:6
相关论文
共 10 条
[1]   Flow cytometric determination of residual leucocytes in filter-depleted blood products: An evaluation of Becton-Dickinson's LeucoCOUNT systems [J].
Barclay, R ;
Walker, B ;
Allan, R ;
Reid, C ;
Duffin, E ;
Kane, E ;
Turner, M .
TRANSFUSION SCIENCE, 1998, 19 (04) :399-403
[2]   Practical guidelines for process validation and process control of white cell-reduced blood components: Report of the biomedical excellence for safer transfusion (BEST) working party of the international society of blood transfusion (ISBT) [J].
Dumont, LJ ;
Dzik, WH ;
Rebulla, P ;
Brandwein, H .
TRANSFUSION, 1996, 36 (01) :11-20
[3]   Principles of counting low numbers of leukocytes in leukoreduced blood components [J].
Dzik, S .
TRANSFUSION MEDICINE REVIEWS, 1997, 11 (01) :44-55
[4]   Are all leucodepleted platelet concentrates equivalent? Comparison of Cobe LRS Turbo, haemonetics MCS plus LD, and filtered pooled buffy-coat-derived platelets [J].
Krailadsiri, P ;
Seghatchian, J .
VOX SANGUINIS, 2000, 78 (03) :171-175
[5]   VALIDATION OF A SIMPLE METHOD TO COUNT VERY LOW WHITE CELL CONCENTRATIONS IN FILTERED RED-CELLS OR PLATELETS [J].
MASSE, M ;
NAEGELEN, C ;
PELLEGRINI, N ;
SEGIER, JM ;
MARPAUX, N ;
BEAUJEAN, F .
TRANSFUSION, 1992, 32 (06) :565-571
[6]   EVALUATION OF THE SINGLE NEEDLE PROCEDURE IN PLATELETPHERESIS WITH THE FRESENIUS AS-104 BLOOD-CELL SEPARATOR [J].
MOOG, R ;
MULLER, N .
JOURNAL OF CLINICAL APHERESIS, 1995, 10 (02) :90-95
[7]  
Moog R, 1997, J CLIN APHERESIS, V12, P126
[8]   Comparison of plateletpheresis concentrates produced with Spectra LRS version 5.1 and LRS Turbo version 7.0 cell separators [J].
Perseghin, P ;
Mascaretti, L ;
Riva, M ;
Sciorelli, G .
TRANSFUSION, 2000, 40 (07) :789-793
[9]   Periodic alternating interface positioning to lower WBC contamination of apheresis platelet concentrates:: a multicenter evaluation [J].
Zeiler, T ;
Zingsem, J ;
Moog, R ;
Kretschmer, V ;
Eckstein, R ;
Müller, N ;
Eisenbeisz, F .
TRANSFUSION, 2000, 40 (06) :687-692
[10]   Evaluation of a platelet apheresis technique for the preparation of leukocyte-reduced platelet concentrates [J].
Zingsem, J ;
Glaser, A ;
Weisbach, V ;
Zimmermann, R ;
Neidhardt, B ;
van Waeg, G ;
Eckstein, R .
VOX SANGUINIS, 1998, 74 (03) :189-192