Statement of problem. Shade tabs in a shade guide are matched to teeth in the order of value, hue, and chroma; therefore, information on the distribution of shade tabs is essential for clinical application of a shade guide. However, there is limited information on the color distribution as sorted by these 3 parameters of a recently introduced shade guide. Purpose. The purposes of this study were to determine the color distributions of tabs from a shade guide in the value (CIE L*), chroma (C*(ab)), and hue scale, and to determine the distribution of step intervals between adjacent tabs by value and chroma. Material and methods. The color of shade tabs (n=29) from a shade guide (Vitapan 3D-Master) was measured to determine the distribution of shade tabs by the value, chroma, hue angle, and CIE a* and b* values. The distribution of the ratios of the value and the chroma of each tab, when compared with the lowest value tab or the lowest chroma tab, was also determined. The data for each color parameter were analyzed by a 3-way ANOVA with the factors of value, chroma, and hue designations of the tabs (alpha=.05). Results. The value, chroma, hue angle, and CIE a* and b* values were influenced by the value, chroma, and hue designations of shade tabs (P <.001). The distributions of the chroma of the tabs within the same value group were relatively ordered, but the values of different value groups overlapped in several instances. Distributions for the CIE a* and b* values reflected the chroma designations in each value group. In the same value group, L, M, and R hue designations corresponded with the manufacturer's stated hue, such as a yellow hue for the L designation and a red hue for the R designation. The distance in the value and chroma scales between adjacent tabs was not uniform. Conclusions. The color distribution of the Vitapan 3D-Master shade guide was more ordered than previously reported color distributions of other, traditional shade guides. However, the interval in the color parameters between adjacent tabs was not uniform; therefore, shade tabs spaced equally, according to the color parameters, should be studied based on the observer's response data.
引用
收藏
页码:18 / 28
页数:11
相关论文
共 35 条
[1]
*AATCC, 2007, 1102005 AATCC
[2]
Designing visually optimal shade guides [J].
Analoui, M ;
Papkosta, E ;
Cochran, M ;
Matis, B .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (04) :371-376
[3]
Baltzer A, 2005, Int J Comput Dent, V8, P129
[4]
INFLUENCE OF WINDOW SIZE IN SMALL-WINDOW COLOR MEASUREMENT, PARTICULARLY OF TEETH [J].
BOLT, RA ;
TENBOSCH, JJ ;
COOPS, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (07) :1133-1142
[5]
Browning William D, 2003, J Esthet Restor Dent, V15 Suppl 1, pS13, DOI 10.1111/j.1708-8240.2003.tb00314.x
[6]
CIE (Commission Internationale de l'Eclairage), 2004, CIE PUB, V15
[7]
Intraoral determination of the tolerance of dentists for perceptibility and acceptability of shade mismatch [J].
Douglas, R. Duane ;
Steinhauer, Tad J. ;
Wee, Alvin G. .
JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (04) :200-208
[8]
Acceptability of shade differences in metal ceramic crowns [J].
Douglas, RD ;
Brewer, JD .
JOURNAL OF PROSTHETIC DENTISTRY, 1998, 79 (03) :254-260
[9]
Ferreira D, 1991, J Dent Assoc S Afr, V46, P63
[10]
TEACHING OF COLOR IN PREDOCTORAL AND POSTDOCTORAL DENTAL EDUCATION IN 1988 [J].
GOODKIND, RJ ;
LOUPE, MJ .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (05) :713-717