Performance of a 2,4-DNPH coated annular denuder/HPLC system for formaldehyde monitoring in air

被引:16
作者
Possanzini, M [1 ]
Di Palo, V [1 ]
机构
[1] CNR, Ist Inquinamento Atmosfer, Area Ric Roma, I-00016 Monterotondo, Roma, Italy
关键词
column liquid chromatography; formaldehyde in air; annular denuder; 2,4-dinitrophenylhydrazine (DNPH);
D O I
10.1007/BF02575279
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of annular denuders coated with 2,4-dinitrophenylhydrazine for collection of atmospheric HCHO has been evaluated by HPLC/UV analysis of samples coming from laboratory tests and field experiments. A number of parameters, such as collection efficiency at varying air humidity, detection limit, operative capacity and temporal self-consistency have been investigated to optimize the denuder behaviour under different weather conditions and to obtain short-term concentration profiles of HCHO. Deviations between measurements made simultaneously by the DNPH denuder method and differential optical absorption spectrometry (DOAS) have been found to average approximately 30 % in the 0-5 ppb HCHO concentration range.
引用
收藏
页码:161 / 165
页数:5
相关论文
共 11 条
[1]   DENUDER TUBES FOR SAMPLING OF GASEOUS SPECIES - A REVIEW [J].
ALI, Z ;
THOMAS, CLP ;
ALDER, JF .
ANALYST, 1989, 114 (07) :759-769
[2]  
BROCCO D, 1992, ACQUA ARIA, V7, P617
[3]   DESIGN AND PERFORMANCE OF A HIGH-VOLUME COMPOUND ANNULAR DENUDER [J].
COUTANT, RW ;
CALLAHAN, PJ ;
KUHLMAN, MR ;
LEWIS, RG .
ATMOSPHERIC ENVIRONMENT, 1989, 23 (10) :2205-2211
[4]  
FEBO A, IN PRESS GAS PARTICL
[5]   MATHEMATICAL TREATMENT OF THE WALL LOSS OF A TRACE SPECIES IN DENUDER AND CATALYTIC-CONVERTER TUBES [J].
MURPHY, DM ;
FAHEY, DW .
ANALYTICAL CHEMISTRY, 1987, 59 (23) :2753-2759
[6]   DETERMINATION OF OLEFINIC ALDEHYDES AND OTHER VOLATILE CARBONYLS IN AIR SAMPLES BY DNPH-COATED CARTRIDGES AND HPLC [J].
POSSANZINI, M ;
DIPALO, V .
CHROMATOGRAPHIA, 1995, 40 (3-4) :134-138
[7]   NEW DESIGN OF A HIGH-PERFORMANCE DENUDER FOR THE SAMPLING OF ATMOSPHERIC POLLUTANTS [J].
POSSANZINI, M ;
FEBO, A ;
LIBERTI, A .
ATMOSPHERIC ENVIRONMENT, 1983, 17 (12) :2605-2610
[8]   DETERMINATION OF LOW BOILING ALDEHYDES IN AIR AND EXHAUST-GASES BY USING ANNULAR DENUDERS COMBINED WITH HPLC TECHNIQUES [J].
POSSANZINI, M ;
CICCIOLI, P ;
DIPALO, V ;
DRAISCI, R .
CHROMATOGRAPHIA, 1987, 23 (11) :829-834
[9]   Measurements of lower carbonyls in Rome ambient air [J].
Possanzini, M ;
Dipalo, V ;
Petricca, M ;
Fratarcangeli, R ;
Brocco, D .
ATMOSPHERIC ENVIRONMENT, 1996, 30 (22) :3757-3764
[10]   3-METHYL-2-BENZOTHIAZOLONE HYDRAZONE TEST - SENSITIVE NEW METHODS FOR DETECTION, RAPID ESTIMATION, AND DETERMINATION OF ALIPHATIC ALDEHYDES [J].
SAWICKI, E ;
ELBERT, W ;
HAUSER, TR ;
STANLEY, TW .
ANALYTICAL CHEMISTRY, 1961, 33 (01) :93-&