Heat transfer analysis of the composite slab in the Cardington frame fire tests

被引:59
作者
Lamont, S [1 ]
Usmani, AS [1 ]
Drysdale, DD [1 ]
机构
[1] Univ Edinburgh, Sch Civil & Environm Engn, Edinburgh EH9 3JN, Midlothian, Scotland
关键词
D O I
10.1016/S0379-7112(01)00041-8
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The structural modelling of the Cardington Frame fire tests as part of the Department of Environment, Transport and Regions funded Partners in Technology project has highlighted the importance of the temperature evolution both temporally and spatially in determining the structural response. Restrained thermal expansion/contraction and thermal bowing are the main driving force behind almost all the structural phenomena witnessed in the tests. The four British Steel fire tests carried out on the 8-storey composite steel and concrete building at Cardington have provided a wealth of information about the temperatures in the fire atmosphere and the protected and unprotected steel. Unfortunately, there is considerably less information on the temperatures attained in the concrete slab. In Tests 1-3, the temperatures through the depth of the slab have been recorded only at a few points and in terms of the structural modelling this has been just about adequate. There were no temperatures recorded in the slab in Test 4 (Office demonstration test). The finite element, adaptive heat transfer program HADAPT has been used to model the heat transfer to the composite steel and concrete slab. HADAPT is a 2D adaptive heat transfer code capable of carrying out a nonlinear, transient, thermal analysis. The code models moisture evaporation from the pores of the concrete by assuming a phase change in the region of 100 degreesC. The measured concrete temperatures in Tests 1-3 have been used to calibrate the model which has then been used to predict the slab temperatures in Test 4. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:815 / 839
页数:25
相关论文
共 33 条
[1]   Modeling pore pressure, moisture, and temperature in high-strength concrete columns exposed to fire [J].
Ahmed, GN ;
Hurst, JP .
FIRE TECHNOLOGY, 1999, 35 (03) :232-262
[2]  
BAZANT ZP, 1979, MAG CONCRETE RES, V31, P61
[3]  
BIZRI H, 1974, 741 UCB FRG
[4]  
BRESLER B, 1974, ASCE NAT STRUCT ENG
[5]  
CHERN JC, 1981, NUCL ENG DES, V68, P61
[7]   HEAT AND MASS-TRANSFER WITHIN AN INTENSELY HEATED CONCRETE SLAB [J].
DAYAN, A ;
GLUEKLER, EL .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1982, 25 (10) :1461-1467
[8]  
DOTREPPE JC, 1986, FIRE SAFETY SCI, P311
[9]   A GENERAL-ANALYSIS OF MOISTURE MIGRATION CAUSED BY TEMPERATURE DIFFERENCES IN AN UNSATURATED POROUS-MEDIUM [J].
ECKERT, ERG ;
FAGHRI, M .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1980, 23 (12) :1613-1623
[10]  
ENV, 1995, Eurocode 2, Design of Concrete Structures, Part 1-2: GeneranRules structure fire Design, S. ENV. 1992-1-2