Mixed oxides prosthetic ceramic ball heads.: Part 1:: effect of the ZrO2 fraction on the wear of ceramic on polyethylene joints

被引:38
作者
Affatato, S
Testoni, M
Cacciari, GL
Toni, A
机构
[1] Ist Ortoped Rizzoli, Lab Biomat Tech, I-40136 Bologna, Italy
[2] Off Ortoped Rizzoli, Bologna, Italy
[3] Univ Bologna, Orthopaed Clin, Bologna, Italy
关键词
mixed-oxide; simulator; bovine calf serum; alumina; zirconia;
D O I
10.1016/S0142-9612(98)00253-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although mixed oxides ceramics have been indicated in the literature as a promising compromise between strength and wear, to the authors' knowledge no reports are available on the influence of the percentage of zirconia in ceramic femoral heads when sliding against polyethylene cups. Two types of mixed oxides ceramic ball heads (alumina plus, respectively, 60 and 80% of zirconia) were compared to pure zirconia and pure alumina heads in terms of wear behaviour against UHMWPE in a hip joint simulator. Polyethylene cups and ceramic femoral heads were fixed on a simulator apparatus with a sinusoidal movement and load in presence of bovine calf serum. The experimental results did not show significant difference between the two experimental ceramic materials or in comparison with pure materials. Considering that all specimens, regardless of the material, had the same level of surface roughness, this roughness factor seems to have a more relevant role than the mix of oxides used to manufacture the ceramic head. Wear tests are conducted on materials used in prosthetic hip implants in order to obtain quality control and to acquire further knowledge of the tribological processes that involve joint prostheses, therefore reducing the risk of implant failure of innovative prostheses. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:971 / 975
页数:5
相关论文
共 29 条
[1]  
Affatato S, 1997, Chir Organi Mov, V82, P393
[2]  
CAMPBELL P, 1991, HIP ARTHROPLASTY, P555
[3]   EVALUATION OF HIP ARTHROPROSTHESES BY MEANS OF BODY ENVIRONMENT SIMULATORS [J].
CAPPOZZO, A ;
CINI, L ;
PIZZOFERRATO, A ;
TRENTANI, C ;
CORTESI, SS .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1977, 11 (05) :657-669
[4]   SOCKET LOOSENING AFTER HIP-ARTHROPLASTY - RADIOGRAPHIC OBSERVATIONS IN 241 CASES UP TO 15 YEARS [J].
CARLSSON, AS ;
GENTZ, CF ;
SANZEN, L .
ACTA ORTHOPAEDICA SCANDINAVICA, 1986, 57 (02) :97-100
[5]   Wear behaviour of alumina toughened zirconia materials [J].
Cherif, K ;
Gueroult, B ;
Rigaud, M .
WEAR, 1996, 199 (01) :113-121
[6]   ROUGHNESS MEASUREMENT WITH A LASER SCANNING ANALYZER [J].
CLARKE, GM ;
THOMAS, TR .
WEAR, 1979, 57 (01) :107-116
[7]   Hip-simulator ranking of polyethylene wear - Comparisons between ceramic heads of different sizes [J].
Clarke, IC ;
Gustafson, A ;
Jung, H ;
Fujisawa, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (02) :128-132
[8]  
CLARKE IC, 1991, HIP ARTHROPLASTY, P535
[9]  
CUCKLER JM, 1995, CLIN ORTHOP RELAT R, P57
[10]  
Fisher J, 1992, J ENG MED, V205