Polycapillary optic-source combinations for protein crystallography

被引:26
作者
Hofmann, FA
Gibson, WM
MacDonald, CA [1 ]
Carter, DA
Ho, JX
Ruble, JR
机构
[1] SUNY Albany, Ctr Xray Opt, Albany, NY 12222 USA
[2] New Century Pharmaceut Inc, Huntsville, AL 35824 USA
关键词
D O I
10.1107/S002188980100468X
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The work in this paper is a systematic study of the application of collimating and slightly focusing polycapillary optics to the X-ray crystallographic structure determination of egg-white lysozyme using two different sources: a standard rotating anode source and a low-power table-top microfocusing source. For the rotating anode source, a series of measurements comparing duplicate data sets obtained from the same individual crystal are summarized. Intensity and data quality are discussed for measurements with a pinhole collimator, a collimating polycapillary optic and a focusing polycapillary optic. The collected data were analyzed using conventional analysis software; limitations of the use of conventional analysis software for focused beams are discussed. Two data sets were collected using the low-power source and collimating optics, and three data sets using a lower-power source and focusing optics with three different limiting apertures.
引用
收藏
页码:330 / 335
页数:6
相关论文
共 10 条
[1]  
DRENTH J, 1999, PRINCIPLES PROTEIN X, P104
[2]  
DRENTH J, 1994, PRINCIPLES PROTEIN C, P285
[3]   Stationary crystal diffraction with a monochromatic convergent X-ray source and application for macromolecular crystal data collection [J].
Ho, JX ;
Snell, EH ;
Sisk, RC ;
Ruble, JR ;
Carter, DC ;
Owens, SM ;
Gibson, WM .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 1998, 54 :200-214
[4]   Focusing of synchrotron radiation with polycapillary optics [J].
Hofmann, FA ;
Freinberg-Trufas, CA ;
Owens, SM ;
Padiyar, SD ;
MacDonald, CA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 133 (1-4) :145-150
[5]  
HOFMANN FA, 1998, MAT RES SOC P, V505
[6]  
Macdonald C A, 1996, J Xray Sci Technol, V6, P32, DOI [10.1006/jxra.1996.0002, 10.3233/XST-1996-6102]
[7]  
MacDonald C. A., 2001, HDB OPTICS, VIII
[8]   Polycapillary X-ray optics for microdiffraction [J].
MacDonald, CA ;
Owens, SM ;
Gibson, WM .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1999, 32 :160-167
[9]   Polycapillary x-ray optics for macromolecular crystallography [J].
Owens, SM ;
Ullrich, JB ;
Ponomarev, IY ;
Carter, DC ;
Sisk, RC ;
Ho, JX ;
Gibson, WM .
HARD X-RAY/GAMMA-RAY AND NEUTRON OPTICS, SENSORS, AND APPLICATIONS, 1996, 2859 :200-209
[10]  
OWENS SM, 1997, THESIS U ALBANY SUNY