Microfluidic electrochemical assay for rapid detection and quantification of Escherichia coli

被引:103
作者
Safavieh, Mohammadali [1 ]
Ahmed, Minhaz Uddin [1 ]
Tolba, Mona [1 ]
Zourob, Mohammed [1 ]
机构
[1] Univ Quebec, INRS EMT, Varennes, PQ J3X 1S2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Biosensor; Microfluidics; Electrochemical detection; Bacteria; Amplification; MEDIATED ISOTHERMAL AMPLIFICATION; BIOSENSORS; SYSTEMS;
D O I
10.1016/j.bios.2011.11.032
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Microfluidic electrochemical biosensor for performing Loop-mediated isothermal amplification (LAMP) was developed for the detection and quantification of Escherichia coli. The electrochemical detection for detecting the DNA amplification was achieved using Hoechst 33258 redox molecule and linear sweep voltametry (LSV). The DNA aggregation and minor groove binding with redox molecule cause a significant drop in the anodic oxidation of LSV. Unlike other electrochemical techniques, this method does not require the probe immobilization and the detection of the bacteria can be accomplished in a single chamber without DNA extraction and purification steps. The isothermal amplification time has a major role in the quantification of the bacteria. We have shown that we could detect and quantify 24 CFU/ml of bacteria and 8.6 fg/mu l DNA in 60 min and 48 CFU/ml of bacteria in 35 min in LB media and urine samples. We believe that this microfluidic chip has great potential to be used as a point of care diagnostic (POC) device in the clinical/hospital application. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:523 / 528
页数:6
相关论文
共 32 条
  • [1] Ahmed M.U., 2008, ELECTROANALYSIS, V20
  • [2] Electrochemical DNA biosensor using a disposable electrochemical printed (DEP) chip for the detection of SNPs from unpurified PCR amplicons
    Ahmed, Minhaz Uddin
    Idegami, Koutarou
    Chikae, Miyuki
    Kerman, Kagan
    Chaumpluk, Piyasak
    Yamamura, Shohei
    Tamiya, Eiichi
    [J]. ANALYST, 2007, 132 (05) : 431 - 438
  • [3] Electrochemical genosensor for the rapid detection of GMO using loop-mediated isothermal amplification
    Ahmed, Minhaz Uddin
    Saito, Masato
    Hossain, M. Mosharraf
    Rao, S. Ramachandara
    Furui, Satoshi
    Hino, Akihiro
    Takamura, Yuzuru
    Takagi, Masahiro
    Tamiya, Eiichi
    [J]. ANALYST, 2009, 134 (05) : 966 - 972
  • [4] POLYMERASE CHAIN-REACTION STRATEGY
    ARNHEIM, N
    ERLICH, H
    [J]. ANNUAL REVIEW OF BIOCHEMISTRY, 1992, 61 : 131 - 156
  • [5] Latest Developments in Micro Total Analysis Systems
    Arora, Arun
    Simone, Giuseppina
    Salieb-Beugelaar, Georgette B.
    Kim, Jung Tae
    Manz, Andreas
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (12) : 4830 - 4847
  • [6] Miniaturized isothermal nucleic acid amplification, a review
    Asiello, Peter J.
    Baeumner, Antje J.
    [J]. LAB ON A CHIP, 2011, 11 (08) : 1420 - 1430
  • [7] Molecular epidemiology of Escherichia coli causing neonatal meningitis
    Bonacorsi, S
    Bingen, E
    [J]. INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2005, 295 (6-7) : 373 - 381
  • [8] Diarrhoeagenic Escherichia coli -: an emerging problem?
    Clarke, SC
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2001, 41 (03) : 93 - 98
  • [9] Electrochemical DNA sensors
    Drummond, TG
    Hill, MG
    Barton, JK
    [J]. NATURE BIOTECHNOLOGY, 2003, 21 (10) : 1192 - 1199
  • [10] Rapid prototyping of microfluidic systems in poly(dimethylsiloxane)
    Duffy, DC
    McDonald, JC
    Schueller, OJA
    Whitesides, GM
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (23) : 4974 - 4984