Radionuclide and metal ion detection on a capillary electrophoresis microchip using LED absorbance detection

被引:27
作者
Collins, GE
Lu, Q
机构
[1] USN, Res Lab, Div Chem, Washington, DC 20375 USA
[2] Geoctr Inc, Rockville, MD 20852 USA
关键词
microchip; arsenato III; PAR; uranium;
D O I
10.1016/S0925-4005(01)00575-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The sensitive and selective detection of various radionuclide, lanthanide and transition metal cations on a capillary electrophoresis (CE) microchip is demonstrated using two different metallochromic complexation ligands, 4-(2-pyridylazo) Resorcinol (PAR) and Arsenate III (AIII). In order to take advantage of the compact and portable potential of a CE microchip, LED absorbance detection was investigated on a simple cross pattern microchip with two different microchannel depths, 20 and 100 mum. Micellar electrokinetic chromatography (MEKC) was utilized on a glass microchip to resolve up to seven different PAR-metal chelates with sub-ppm detection limits within a minute. Microchip determinations of U(VI) were performed using the colorimetric metal complexation ligand, Arsenate III, utilizing absorbance detection with a red LED light source and a photodiode array detector. A mixture of UO22+ and three interference metal ions were separated on a microchip, and the addition of EDTA to the background electrolyte (BGE) is demonstrated to be an effective means of eliminating any interference from lanthanide and transition metal ions. Published by Elsevier Science B.V.
引用
收藏
页码:244 / 249
页数:6
相关论文
共 15 条
[1]  
CHENG KL, 1992, CRC HDB ORGANIC ANAL, P195
[2]   Development and operating characteristics of micro flow injection analysis systems based on electroosmotic flow - A review [J].
Haswell, SJ .
ANALYST, 1997, 122 (01) :R1-R10
[3]   HIGH-PERFORMANCE SEPARATION AND DETERMINATION OF CO(III) AND NI(II) CHELATES OF 4-(2-PYRIDYLAZO)RESORCINOL AT FEMTOMOLE LEVELS BY CAPILLARY ELECTROPHORESIS [J].
IKI, N ;
HOSHINO, H ;
YOTSUYANAGI, T .
CHEMISTRY LETTERS, 1993, (04) :701-704
[4]   FUSED QUARTZ SUBSTRATES FOR MICROCHIP ELECTROPHORESIS [J].
JACOBSON, SC ;
MOORE, AW ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2059-2063
[5]  
Kutter JP, 1998, J MICROCOLUMN SEP, V10, P313, DOI 10.1002/(SICI)1520-667X(1998)10:4<313::AID-MCS1>3.0.CO
[6]  
2-J
[7]   Separation of uranium(VI) and lanthanides by capillary electrophoresis using on-capillary complexation with arsenate III [J].
Macka, M ;
Nesterenko, P ;
Andersson, P ;
Haddad, PR .
JOURNAL OF CHROMATOGRAPHY A, 1998, 803 (1-2) :279-290
[8]   Determination of metal ions by capillary electrophoresis [J].
Macka, M ;
Haddad, PR .
ELECTROPHORESIS, 1997, 18 (12-13) :2482-2501
[9]   Comparison of adsorptive stripping voltammetry (AdSV) and capillary zone electrophoresis (CZE) for the trace determination of selected metal ions, chelated with 2-(5'-bromo-2'-pyridylazo)-5-(diethylamino)phenol (PADAP) [J].
Oxspring, DA ;
Maxwell, TJ ;
Smyth, WF .
ANALYTICAL PROCEEDINGS, 1995, 32 (12) :489-491
[10]   NEAR-INFRARED FLUOROGENIC LABELS - NEW APPROACH TO AN OLD PROBLEM [J].
PATONAY, G ;
ANTOINE, MD .
ANALYTICAL CHEMISTRY, 1991, 63 (06) :A321-A326