Removal of Zn(II), Cu(II), Ni(II), Ag(I) and Cr(VI) present in aqueous solutions by aluminium electrocoagulation

被引:333
作者
Heidmann, Ilona [1 ]
Calmano, Wolfgang [1 ]
机构
[1] Hamburg Univ Technol, Inst Environm Technol & Energy Econ, D-21073 Hamburg, Germany
关键词
electrocoagulation; heavy metals; aluminium electrodes; industrial wastewater;
D O I
10.1016/j.jhazmat.2007.07.068
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance of an electrocoagulation system with aluminium electrodes for removing heavy metal ions (Zn2+, Cu2+, Ni2+, Ag+, Cr2O72-) on laboratory scale was studied systematically. Several parameters - such as initial metal concentration, numbers of metals present, charge loading and current density - and their influence on the electrocoagulation process were investigated. Initial concentrations from 50 to 5000mgL(-1) Zn, Cu, Ni and Ag did not influence the removal rates, whereas higher initial concentrations caused higher removal rates of Cr. Increasing the current density accelerated the electrocoagulation process but made it less efficient. Zn, Cu and Ni showed similar removal rates indicating a uniform electrochemical behavior. The study gave indications on the removal mechanisms of the investigated metals. Zn, Cu, Ni and Ag ions are hydrolyzed and co-precipitated as hydroxides. Cr(VI) was proposed to be reduced first to Cr(HI) at the cathode before precipitating as hydroxide. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:934 / 941
页数:8
相关论文
共 24 条
[1]   Treatment of electroplating wastewater containing Cu2+, Zn2+ and Cr(VI) by electrocoagulation [J].
Adhoum, N ;
Monser, L ;
Bellakhal, N ;
Belgaied, JE .
JOURNAL OF HAZARDOUS MATERIALS, 2004, 112 (03) :207-213
[2]  
*APHA AWWA WPCF, 2005, STAND METH EX WAT WA, V21
[3]   Chemical and electrochemical considerations on the removal process of hexavalent chromium from aqueous media [J].
Barrera-Díaz, C ;
Palomar-Pardavé, M ;
Romero-Romo, M ;
Martínez, S .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2003, 33 (01) :61-71
[4]   Electrochemical technologies in wastewater treatment [J].
Chen, GH .
SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 38 (01) :11-41
[5]   Electrocoagulation and electroflotation of restaurant wastewater [J].
Chen, GH ;
Chen, XM ;
Yue, PL .
JOURNAL OF ENVIRONMENTAL ENGINEERING, 2000, 126 (09) :858-863
[6]   Removal of chromium(VI) from wastewater by combined electrocoagulation-electroflotation without a filter [J].
Gao, P ;
Chen, XM ;
Shen, F ;
Chen, GH .
SEPARATION AND PURIFICATION TECHNOLOGY, 2005, 43 (02) :117-123
[7]   Deciphering the science behind electrocoagulation to remove suspended clay particles from water [J].
Holt, PK ;
Barton, GW ;
Mitchell, CA .
WATER SCIENCE AND TECHNOLOGY, 2004, 50 (12) :177-184
[8]   A quantitative comparison between chemical dosing and electrocoagulation [J].
Holt, PK ;
Barton, GW ;
Wark, M ;
Mitchell, CA .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2002, 211 (2-3) :233-248
[9]   Electrochemical treatment of heavy metals (Cu2+, Cr6+Ni2+) from industrial effluent and modeling of copper reduction [J].
Hunsom, M ;
Pruksathorn, K ;
Damronglerd, S ;
Vergnes, H ;
Duverneuil, P .
WATER RESEARCH, 2005, 39 (04) :610-616
[10]   ELECTROPRECIPITATION TREATMENT OF ACID-MINE WASTEWATER [J].
JENKE, DR ;
DIEBOLD, FE .
WATER RESEARCH, 1984, 18 (07) :855-859