In a matched-pair study of primary total hip arthroplasty, 45 all-polyethylene cemented acetabular components were compared with 45 cementless, hemispheric, titanium acetabular components. At 9 to 12 years, I of the cemented acetabular components was revised for aseptic loosening, and 14 (31%) were radiographically loose. Nine (20%) cemented acetabular components had pelvic osteolysis. In the cementless acetabular component group, 2 well-fixed components were revised. No components were radiographically loose, and 3 (7%) had pelvic osteolysis. Thirty-eight (97%) of the patients in each group were satisfied with the surgery. The clinical results of the cemented and cementless components were excellent. The cementless components had less loosening (P < .001) than the cemented components.
引用
收藏
页码:697 / 705
页数:9
相关论文
共 36 条
[1]
ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[2]
CALLAGHAN JJ, 1998, ANN M AM ASS HIP KNE
[3]
Charnley J.P., 1979, LOW FRICTION ANTHROP
[4]
Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement - An average ten-year follow-up study [J].
Clohisy, JC ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (02) :247-255
[5]
The Harris-Galante uncemented femoral component in primary total hip replacement at 10 years [J].
Clohisy, JC ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 1999, 14 (08) :915-917
[6]
The Harris-Galante porous-coated acetabular component with screw fixation - An average ten-year follow-up study [J].
Clohisy, JC ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01) :66-73
[7]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[8]
DUFFY GP, 1998, ANN M AM ASS HIP KNE
[9]
GALANTE JO, 1997, PRIMARY CEMENTLESS A
[10]
EARLY AND LATE LOOSENING OF THE ACETABULAR CUP AFTER LOW-FRICTION ARTHROPLASTY [J].
GARCIACIMBRELO, E ;
MUNUERA, L .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (08) :1119-1129