The Biomechanical Effect of Torsion on Humeral Shaft Repair Techniques for Completed Pathological Fractures

被引:14
作者
Al-Jahwari, Ahmed [1 ]
Schemitsch, Emil H. [3 ]
Wunder, Jay S. [4 ,5 ]
Ferguson, Peter C. [4 ,5 ]
Zdero, Rad [1 ,2 ]
机构
[1] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
[2] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON M5B 2K3, Canada
[3] St Michaels Hosp, Div Orthopaed Surg, Toronto, ON M5B 1W8, Canada
[4] Mt Sinai Hosp, Dept Surg, Univ Musculoskeletal Oncol Unit, Toronto, ON M5G 1X5, Canada
[5] Mt Sinai Hosp, Dept Surg, Div Orthopaed Surg, Toronto, ON M5G 1X5, Canada
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2012年 / 134卷 / 02期
关键词
biomechanics; humerus; tumor; fracture; fixation; pathological; TOTAL HIP IMPLANT; PROXIMAL HUMERUS; PLATE OSTEOSYNTHESIS; INTRAMEDULLARY NAIL; INTERNAL-FIXATION; SYNTHETIC FEMURS; DESIGN; SYSTEMS; TIP;
D O I
10.1115/1.4005696
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
In the presence of a tumor defect, completed humeral shaft fractures continue to be a major surgical challenge since there is no "gold standard" treatment. This is due, in part, to the fact that only one prior biomechanical study exists on the matter, but which only compared 2 repair methods. The current authors measured the humeral torsional performance of 5 fixation constructs for completed pathological fractures. In 40 artificial humeri, a 2-cm hemi-cylindrical cortical defect with a transverse fracture was created in the lateral cortex. Specimens were divided into 5 different constructs and tested in torsion. Construct A was a broad 10-hole 4.5-mm dynamic compression plate (DCP). Construct B was the same as A except that the screw holes and the tumor defect were filled with bone cement and the screws were inserted into soft cement. Construct C was the same as A except that the canal and tumor defect were filled with bone cement and the screws were inserted into dry cement. Construct D was a locked intramedullary nail inserted in the antegrade direction. Construct E was the same as D except that bone cement filled the defect. For torsional stiffness, construct C (4.45 +/- 0.20 Nm/deg) was not different than B or E (p > 0.16), but was higher than A and D (p < 0.001). For failure torque, construct C achieved a higher failure torque (69.65 +/- 5.35 Nm) than other groups (p < 0.001). For the failure angle, there were no differences between plating constructs A to C (p >= 0.11), except for B versus C (p < 0.05), or between nailing groups D versus E (p = 0.97), however, all plating groups had smaller failure angles than both nailing groups (p < 0.05). For failure energy, construct C (17.97 +/- 3.59 J) had a higher value than other groups (p < 0.005), except for A (p = 0.057). Torsional failure always occurred in the bone in the classic "spiral" pattern. Construct C provided the highest torsional stability for a completed pathological humeral shaft fracture. [DOI: 10.1115/1.4005696]
引用
收藏
页数:7
相关论文
共 40 条
[1]
Function after resection of humeral metastases - Analysis of 59 consecutive patients [J].
Bickels, J ;
Kollender, Y ;
Wittig, JC ;
Meller, I ;
Malawer, MM .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (437) :201-208
[2]
The biomechanics of a validated finite element model of stress shielding in a novel hybrid total knee replacement [J].
Bougherara, H. ;
Zdero, R. ;
Mahboob, Z. ;
Dubov, A. ;
Shah, S. ;
Schemitsch, E. H. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H10) :1209-1219
[3]
The biomechanics of the T2 femoral nailing system: a comparison of synthetic femurs with finite element analysis [J].
Bougherara, H. ;
Zdero, R. ;
Miric, M. ;
Shah, S. ;
Hardisty, M. ;
Zalzal, P. ;
Schemitsch, E. H. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H3) :303-314
[4]
Campanacci M., 1999, BONE SOFT TISSUE TUM
[5]
CHIN HC, 1989, CLIN ORTHOP RELAT R, P231
[6]
A BIOMECHANICAL COMPARISON OF INTRAMEDULLARY NAILING SYSTEMS FOR THE HUMERUS [J].
DALTON, JE ;
SALKELD, SL ;
SATTERWHITE, YE ;
COOK, SD .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1993, 7 (04) :367-374
[7]
Damron TA, 1999, CLIN ORTHOP RELAT R, P240
[8]
A Biomechanical and Finite Element Analysis of Femoral Neck Notching During Hip Resurfacing [J].
Davis, Edward T. ;
Olsen, Michael ;
Zdero, Rad ;
Papini, Marcello ;
Waddell, James P. ;
Schemitsch, Emil H. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (04)
[9]
Treatment of pathological fractures of the humeral shaft due to bone metastases: A comparison of intramedullary locking nail and plate osteosynthesis with adjunctive bone cement [J].
Dijkstra, S ;
Stapert, J ;
Boxma, H ;
Wiggers, T .
EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 1996, 22 (06) :621-626
[10]
The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant: the effect of cable-screw position [J].
Dubov, A. ;
Kim, S. Y. R. ;
Shah, S. ;
Schemitsch, E. H. ;
Zdero, R. ;
Bougherara, H. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H9) :857-865