A randomized, single-blind, increasing dose safety trial of an oxygen-carrying plasma expander (Hemospan®) administered to orthopaedic surgery patients with spinal anaesthesia

被引:36
作者
Olofsson, C. [1 ]
Nygards, E. B. [1 ]
Ponzer, S. [2 ]
Fagrell, B. [1 ]
Przybelski, R. [3 ]
Keipert, P. E. [4 ]
Winslow, N. [4 ]
Winslow, R. M. [4 ,5 ]
机构
[1] Karolinska Univ Hosp, Dept Anaesthesiol, Stockholm, Sweden
[2] Karolinska Inst Sodersjukhuset, Dept Clin Sci & Educ, Stockholm, Sweden
[3] Univ Wisconsin, Dept Geriatr Med & Gerontol, Madison, WI USA
[4] Sangart Inc, San Diego, CA 92121 USA
[5] Univ Calif San Diego, Dept Bioengn, San Diego, CA 92103 USA
关键词
blood substitutes; clinical trials; haemoglobin; haemoglobin-based oxygen carriers; MP4; oxygen therapeutics; PEG; spinal anaesthesia;
D O I
10.1111/j.1365-3148.2007.00811.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The objective of this study was to further explore the safety of Hemospan (R) (Sangart Inc., San Diego, CA, USA), an oxygen-carrying plasma expander. The aim of this study was to determine if Hemospan is well tolerated in orthopaedic surgery patients with spinal anaesthesia in doses up to 1 L. Hemospan was previously found to be well tolerated in normal volunteers and orthopaedic surgery patients with spinal anaesthesia in doses up to 500 mL. Five cohorts of six orthopaedic surgery patients, American Society of Anesthesiologists (ASA) I and II, were studied. In each cohort, four patients received Hemospan in doses ranging from 200 to 1000 mL, and two received Ringer's lactate immediately prior to induction of spinal anaesthesia. There were no serious adverse events (SAEs). Iohexol clearance measured before and 24 h after dosing was unaffected. There were 14 adverse events (AEs) in the 10 control patients (1.4 per patient) and 30 in the 20 patients receiving Hemospan (1.5 per patient). One patient in the group receiving 200 mL Hemospan had elevated mean arterial pressure after dosing, but there were no elevations in any of the other patients. The peak plasma Hemospan concentration in the 1000 mL group was 1.3 g dL(-1), with a dose-dependent clearance (T-1/2) ranging from 14.1 to 23.0 h. Plasma methaemoglobin levels were independent of dose, reaching a maximum at 40 h after dosing and never exceeded 0.125 g dL(-1). Troponin T was transiently elevated in two patients receiving Hemospan without symptoms or electrocardiographic abnormalities or elevation of myocardial creatinine kinase isoenzyme. Hemospan was well tolerated in this group of patients at doses up to 1000 mL.
引用
收藏
页码:28 / 39
页数:12
相关论文
共 20 条
[1]  
Björkholm M, 2005, HAEMATOLOGICA, V90, P505
[2]   A phase II dose-response study of hemoglobin raffimer (Hemolink) in elective coronary artery bypass surgery [J].
Cheng, DCH ;
Mazer, CD ;
Martineau, R ;
Ralph-Edwards, A ;
Karski, J ;
Robblee, J ;
Finegan, B ;
Hall, RI ;
Latimer, R ;
Vuylsteke, A .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (01) :79-86
[3]   A quantitative framework for the design of acellular hemoglobins as blood substitutes: Implications of dynamic flow conditions [J].
Cole, Russell H. ;
Vandegriff, Kim D. ;
Szeri, Andrew J. ;
Savas, Omer ;
Baker, Dale A. ;
Winslow, Robert M. .
BIOPHYSICAL CHEMISTRY, 2007, 128 (01) :63-74
[4]   Hemodynamic response and oxygen transport in pigs resuscitated with maleimide-polyethylene glycol-modified hemoglobin (MP4) [J].
Drobin, D ;
Kjellstrom, BT ;
Malm, E ;
Malavalli, A ;
Lohman, J ;
Vandegriff, KD ;
Young, MA ;
Winslow, RM .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (05) :1843-1853
[5]  
Evelyn KA, 1938, J BIOL CHEM, V126, P655
[6]   Haemodynamic effects of diaspirin crosslinked haemoglobin (DCLHb) given before abdominal aortic aneurysm surgery [J].
Garrioch, MA ;
McClure, JH ;
Wildsmith, JAW .
BRITISH JOURNAL OF ANAESTHESIA, 1999, 83 (05) :702-707
[7]   Safety and preliminary efficacy of hemoglobin raffimer for patients undergoing coronary artery bypass surgery [J].
Hill, SE ;
Gottschalk, LI ;
Grichnik, K .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (06) :695-702
[8]   The role of facilitated diffusion in oxygen transport by cell-free hemoglobins: implications for the design of hemoglobin-based oxygen carriers [J].
McCarthy, MR ;
Vandegriff, KD ;
Winslow, RM .
BIOPHYSICAL CHEMISTRY, 2001, 92 (1-2) :103-117
[9]   Low-dose bupivacaine with sufentanil prevents hypotension after spinal anesthesia for hip repair in elderly patients [J].
Olofsson, C ;
Nygårds, EB ;
Bjersten, AB ;
Hessling, A .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2004, 48 (10) :1240-1244
[10]   A multicenter clinical study of the safety and activity of maleimide-polyethylene glycol-modified hemoglobin (Hemospan®) in patients undergoing major orthopedic surgery [J].
Olofsson, Christina ;
Ahl, Torbjorn ;
Johansson, Torsten ;
Larsson, Sune ;
Nellgard, Per ;
Ponzer, Sari ;
Fagrell, Bengt ;
Przybelski, Robert ;
Keipert, Peter ;
Winslow, Nancy ;
Winslow, Robert M. .
ANESTHESIOLOGY, 2006, 105 (06) :1153-1163