Hollow metal microneedles for insulin delivery to diabetic rats

被引:308
作者
Davis, SP
Martanto, W
Allen, MG [1 ]
Prausnitz, MR
机构
[1] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Sch Chem & Biomol Engn, Atlanta, GA 30332 USA
基金
美国国家卫生研究院;
关键词
drug delivery systems; laser machining; micromachining;
D O I
10.1109/TBME.2005.845240
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The goal of this study was to design, fabricate, and test arrays of hollow microneedles for minimally invasive and continuous delivery of insulin in vivo. As a simple, robust fabrication method suitable for inexpensive mass production, we developed a modified-LIGA process to micromachine molds out of polyethylene terephthalate using an ultraviolet laser, coated those molds with nickel by electrodepostion onto a sputter-deposited seed layer, and released the resulting metal microneedle arrays by selectively etching the polymer mold. Mechanical testing showed that these microneedles were sufficiently strong to pierce living skin without breaking. Arrays containing 16 microneedles measuring 500 mu m in length with a 75 mu m tip diameter were then inserted into the skin of anesthetized, diabetic, hairless rats. Insulin delivery through microneedles caused blood glucose levels to drop steadily to 47% of pretreatment values over a 4-h insulin delivery period and were then approximately constant over a 4-h postdelivery monitoring period. Direct measurement of plasma insulin levels showed a peak value of 0.43 ng/ml. Together, these data suggest that microneedles can be fabricated and used for in vivo insulin delivery.
引用
收藏
页码:909 / 915
页数:7
相关论文
共 27 条
[1]
Scaling basic toxicokinetic parameters from rat to man [J].
Bachmann, K ;
Pardoe, D ;
White, D .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1996, 104 (04) :400-407
[2]
Microfabricated silicon microneedles for nonviral cutaneous gene delivery [J].
Chabri, F ;
Bouris, K ;
Jones, T ;
Barrow, D ;
Hann, A ;
Allender, C ;
Brain, K ;
Birchall, J .
BRITISH JOURNAL OF DERMATOLOGY, 2004, 150 (05) :869-877
[3]
CHEN J, 2001, IEEE T BIOMED ENG, V44, P760
[4]
Davidson M.B., 1998, DIABETES MELLITUS DI
[5]
Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force [J].
Davis, SP ;
Landis, BJ ;
Adams, ZH ;
Allen, MG ;
Prausnitz, MR .
JOURNAL OF BIOMECHANICS, 2004, 37 (08) :1155-1163
[6]
Silicon micromachined hollow microneedles for transdermal liquid transport [J].
Gardeniers, HJGE ;
Luttge, R ;
Berenschot, EJW ;
de Boer, MJ ;
Yeshurun, SY ;
Hefetz, M ;
van't Oever, R ;
van den Berg, A .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2003, 12 (06) :855-862
[7]
HASHMI S, 1995, BIOTECHNIQUES, V19, P766
[8]
Microfabricated microneedles: A novel approach to transdermal drug delivery [J].
Henry, S ;
McAllister, DV ;
Allen, MG ;
Prausnitz, MR .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1998, 87 (08) :922-925
[9]
Lack of pain associated with microfabricated microneedles [J].
Kaushik, S ;
Hord, AH ;
Denson, DD ;
McAllister, DV ;
Smitra, S ;
Allen, MG ;
Prausnitz, MR .
ANESTHESIA AND ANALGESIA, 2001, 92 (02) :502-504
[10]
Challenges in optimal metabolic control of diabetes [J].
Liebl, A .
DIABETES-METABOLISM RESEARCH AND REVIEWS, 2002, 18 :S36-S41