Visualization of Cerebral Microbleeds With Dual-Echo T2*-Weighted Magnetic Resonance Imaging at 7.0 T

被引:29
作者
Conijn, Mandy M. A. [1 ,2 ]
Geerlings, Mirjam I. [2 ]
Luijten, Peter R. [1 ,3 ]
Zwanenburg, Jaco J. M. [1 ,3 ]
Visser, Fredy [4 ]
Biessels, Geert Jan [5 ]
Hendrikse, Jeroen [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, NL-3508 GA Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Image Sci Inst, NL-3508 GA Utrecht, Netherlands
[4] Philips Healthcare, Best, Netherlands
[5] Univ Med Ctr Utrecht, Dept Neurol, NL-3508 GA Utrecht, Netherlands
关键词
microbleeds; 7 T MRI; hemosiderin; INTRACEREBRAL HEMORRHAGE; ISCHEMIC-STROKE; RISK-FACTORS; BRAIN IRON; MRI; PREVALENCE; ASSOCIATIONS; HEMOSIDERIN; DISEASE; FOCI;
D O I
10.1002/jmri.22223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the visualization of cerebral microbleeds with dual echo T2*-weighted imaging at 7.0 T magnetic resonance imaging (MRI). Materials and Methods: Ten consecutive participants (eight men, two women, mean age 54 12 years) with vascular disease or risk factors from the second manifestations of arterial disease (SMART) study were included. Dual-echo T2*-weighted scans (echo time: 2.5/15.0 msec) were made for all participants at 7.0 T MRI. The number of visible microbleeds and the diameter of the microbleeds were recorded on minimal intensity projection images of both echoes. Results: The first echo image shows dark microbleeds against a homogeneous, more hyperintense signal of the brain tissue without contrast for veins and basal ganglia. In eight patients microbleeds were observed, with a total of 104 microbleeds. Of these, 88 (84.6%) were visible on the first and 102 (98.0%) on the second echo. The mean diameter of the microbleeds was 1.24 mm for the first echo and 2.34 mm for the second echo. Conclusion: T2*-weighted imaging at two echo times at 7.0 T combines the advantages of the first and second echo. Microbleeds visible on the first echo show large contrast with the surrounding tissue, even in the presence of paramagnetic ferritin. The second echo enables visualization of smaller microbleeds than the first echo.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 33 条
[1]   Detection of hemorrhagic hypointense foci in the brain on susceptibility-weighted imaging: Clinical and phantom studies [J].
Akter, Masuma ;
Hirai, Toshinori ;
Hiai, Yasuhiro ;
Kitajima, Mika ;
Komi, Masanori ;
Murakami, Ryuji ;
Fukuoka, Hirofumi ;
Sasao, Akira ;
Toya, Ryo ;
Haacke, E. Mark ;
Takahashi, Mutsumasa ;
Hirano, Teruyuki ;
Kai, Yutaka ;
Morioka, Motohirc ;
Hamasaki, Kiyotoshi ;
Kuratsu, Jun-Ichi ;
Yamashita, Yasuyuki .
ACADEMIC RADIOLOGY, 2007, 14 (09) :1011-1019
[2]   On the artifact of a subvoxel susceptibility deviation in spoiled gradient-echo imaging [J].
Bos, C ;
Viergever, MA ;
Bakker, CJG .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (02) :400-404
[3]   MR APPEARANCE OF HEMORRHAGE IN THE BRAIN [J].
BRADLEY, WG .
RADIOLOGY, 1993, 189 (01) :15-26
[4]   Prevalence and severity of microbleeds in a memory clinic setting [J].
Cordonnier, C ;
van der Flier, WM ;
Sluimer, JD ;
Leys, D ;
Barkhof, F ;
Scheltens, P .
NEUROLOGY, 2006, 66 (09) :1356-1360
[5]   Simultaneous acquisition of MR angiography and venography (MRAV) [J].
Du, Yiping P. ;
Jin, Zhaoyang .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (05) :954-958
[6]  
Fazekas F, 1999, AM J NEURORADIOL, V20, P637
[7]   Bleeding Risk Analysis in Stroke Imaging before ThromboLysis (BRASIL) -: Pooled analysis of t2*-weighted magnetic resonance imaging data from 570 patients [J].
Fiehler, Jens ;
Albers, Gregory W. ;
Boulanger, Jean-Martin ;
Derex, Laurent ;
Gass, Achim ;
Hjort, Niels ;
Kim, Jong S. ;
Liebeskind, David S. ;
Neumann-Haefelin, Tobias ;
Pedraza, Salvador ;
Rother, Joachim ;
Rothwell, Peter ;
Rovira, Alex ;
Schellinger, Peter D. ;
Trenkler, Johannes .
STROKE, 2007, 38 (10) :2738-2744
[8]   Cerebral microbleeds: a guide to detection and interpretation [J].
Greenberg, Steven M. ;
Vernooij, Meike W. ;
Cordonnier, Charlotte ;
Viswanathan, Anand ;
Salman, Rustorn Al-Shahi ;
Warach, Steven ;
Launer, Lenore J. ;
Van Buchem, Mark A. ;
Breteler, Monique M. B. .
LANCET NEUROLOGY, 2009, 8 (02) :165-174
[9]   Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1 [J].
Haacke, E. M. ;
Mittal, S. ;
Wu, Z. ;
Neelavalli, J. ;
Cheng, Y. -C. N. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (01) :19-30
[10]   MR contrast of ferritin and hemosiderin in the brain: comparison among gradient-echo, conventional spin-echo and fast spin-echo sequences [J].
Haque, TL ;
Miki, Y ;
Kanagaki, M ;
Takahashi, T ;
Yamamoto, A ;
Konishi, J ;
Nozaki, K ;
Hashimoto, N ;
Konishi, J .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 48 (03) :230-236