The analog signal processing system for the Auger fluorescence detector prototype

被引:2
作者
Argirò, S [1 ]
Camin, DV
Cattaneo, P
Cuautle, M
Destro, M
Facal, P
Gariboldi, R
Grassi, V
Lapolla, M
Manfredi, P
Menichetti, E
Privitera, P
Ratti, L
Re, V
Speziali, V
Trapani, P
Tusi, E
机构
[1] Univ Turin, Dept Phys, I-10125 Turin, Italy
[2] Univ Milan, I-20122 Milan, Italy
[3] Ist Nazl Fis Nucl, Sez Torino, Turin, Italy
[4] Univ Autonoma Puebla, Puebla, Mexico
[5] Univ Roma Tor Vergata, Rome, Italy
[6] Univ Santiago de Compostela, Santiago De Compostela, Spain
[7] Univ Pavia, I-27100 Pavia, Italy
[8] Univ Bergamo, Bergamo, Italy
关键词
analog signal processing; fluoresecence detectors; ultra high energy cosmic rays;
D O I
10.1109/23.940097
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The fluorescence detector of the Pierre Auger Cosmic Ray Observatory will provide a measurement of the parameters of extended air showers in the range from 10(19) to 10(21) eV. An array of 20 X 22 photomultiplier tubes (PMTs) is placed at the focal surface of a large-aperture telescope thus forming one of the 30 detector modules. The shape of the signal generated by each PMT is variable, depending mostly on the geometry of the air shower as seen by the detector; after analog processing the waveforms will be sampled at a rate of 10 MHz with 12-bit resolution. We have developed an analog signal processor to achieve the best compromise between energy and time resolution, low noise, and low cost. The head electronics provides an active bias network for the PMTs, which keeps the gain constant even in the presence of large dc background light from the night sky. This de level is measured by means of a built-in optocoupled linear circuit. The pulse signal is sent through a twisted pair to the analog front-end board. At this stage a compression of the 15-bit dynamic range of the signal into the 12-bit range of the FADC is performed. Antialiasing is provided ky a Bessel filter.
引用
收藏
页码:444 / 449
页数:6
相关论文
共 13 条
[1]   Monitoring DC anode current of a grounded-cathode photomultiplier tube [J].
Argirò, S ;
Camin, DV ;
Destro, M ;
Guérard, CK .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 435 (03) :484-489
[2]   The analog signal processor of the Auger fluorescence detector prototype [J].
Argirò, S ;
Camin, DV ;
Cattaneo, P ;
Destro, M ;
Fonte, R ;
Gariboldi, R ;
Grassi, V ;
Lapolla, M ;
Manfredi, PF ;
Menichetti, E ;
Nicotra, M ;
Privitera, P ;
Ratti, L ;
Re, V ;
Speziali, V ;
Trapani, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 461 (1-3) :440-448
[3]  
ARGIRO S, 2000, SUNFLOWER TEST RESUL
[4]  
ARGIRO S, 1999, PASSIVE ACTIVE PMT B
[5]  
*AUG COLL, 1977, P AUG OBS DES REP
[6]  
CAMIN D, 1999, ANALOG PROCESSING SI
[7]  
CAMIN DV, 1999, FABRICATION 1 150 HE
[8]  
CATTANEO P, 1999, ANTIALIASING REQUIRE
[9]  
DAWSON B, 1997, AMPLITUDE DYNAMIC RA
[10]  
DAWSON B, 1999, AMPLITUDE DYNAMIC RA