X-ray phase contrast tomography with a bending magnet source

被引:25
作者
Peele, AG [1 ]
De Carlo, F
McMahon, PJ
Dhal, BB
Nugent, KA
机构
[1] La Trobe Univ, Dept Phys, Bundoora, Vic 3086, Australia
[2] Argonne Natl Lab, Argonne, IL 60439 USA
[3] Univ Melbourne, Sch Phys, Melbourne, Vic 3010, Australia
基金
澳大利亚研究理事会;
关键词
D O I
10.1063/1.2005447
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
X-ray radiography and x-ray tomography are important tools for noninvasive characterization of materials. Historically, the contrast mechanism used with these techniques has been absorption. However, for any given sample there are x-ray energies for which absorption contrast is poor. Alternatively, when good contrast can be obtained, radiation damage from an excessive dose may become an issue. Consequently, phase-contrast methods have in recent years been implemented at both synchrotron and laboratory facilities. A range of radiographic and tomographic demonstrations have now been made, typically utilizing the coherent flux from an insertion device at a synchrotron or a microfocus laboratory source. In this paper we demonstrate that useful results may be obtained using a bending magnet source at a synchrotron. In particular we show that the same beamline can be used to make and characterize a sample made by x-ray lithographic methods. (c) 2005 American Institute of Physics.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 38 条
[1]   Exit wave reconstruction using soft X-rays [J].
Allen, LJ ;
McBride, W ;
Oxley, MP .
OPTICS COMMUNICATIONS, 2004, 233 (1-3) :77-82
[2]  
Attwood D., 1999, SOFT XRAYS EXTREME U, P371
[3]  
Becker E. W., 1986, Microelectronic Engineering, V4, P35, DOI 10.1016/0167-9317(86)90004-3
[4]  
BECKER EW, 1982, NATURWISSENSCHAFTEN, V69, P520, DOI 10.1007/BF00463495
[5]  
BECKMANN F, 1997, J COMPUT ASSIST TOMO, V21, P535
[7]   THEORETICAL FORM-FACTOR, ATTENUATION AND SCATTERING TABULATION FOR Z=1-92 FROM E=1-10 EV TO E=0.4-1.0 MEV [J].
CHANTLER, CT .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1995, 24 (01) :71-591
[8]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[9]   Phase-retrieval X-ray microscopy by Wigner-distribution deconvolution [J].
Chapman, HN .
ULTRAMICROSCOPY, 1996, 66 (3-4) :153-172
[10]   Performance of a double-multilayer monochromator at Beamline 2-BM at the Advanced Photon Source [J].
Chu, YS ;
Liu, C ;
Mancini, DC ;
De Carlo, F ;
Macrander, AT ;
Lai, B ;
Shu, D .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (03) :1485-1487