Characterization of oxygen transfer in miniature and lab-scale bubble column bioreactors and comparison of microbial growth performance based on constant kLα

被引:27
作者
Doig, SD
Ortiz-Ochoa, K
Ward, JM
Baganz, F
机构
[1] UCL, Adv Ctr Biochem Engn, London WC1E 7JE, England
[2] UCL, Dept Biochem & Mol Biol, London WC1E 6BT, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1021/bp050064j
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This work describes the engineering characterization of miniature (2 mL) and laboratory-scale (100 mL) bubble column bioreactors useful for the cultivation of microbial cells. These bioreactors were constructed of glass and used a range of sintered glass gas diffusers with differently sized pores to disperse humidified air within the liquid biomedium. The effect of the pressure of this supplied air on the breakthrough point for gas diffusers with different pore sizes was examined and could be predicted using the Laplace-Young equation. The influence of the superficial gas velocity (u(g)) on the volumetric mass transfer coefficient (k(L)a) was determined, and values of up to 0.09 s(-1) were observed in this work. Two modeling approaches were considered in order to predict and provide comparison criteria. The first related the volumetric power consumption (P/V) to the k(L)a and a good correlation was obtained for differently sized reactors with a given pore size, but this correlation was not satisfactory for bubble columns with different gas diffusers. Values for P/V ranged from about 10 to 400 W center dot m(-3). Second, a model was developed predicting bubble size (d(b)), bubble rising velocity (u(b)), gas hold-up (phi), liquid side mass transfer coefficient (k(L)), and thus the kLa using established theory and empirical correlations. Good agreement was found with our experimental data at different scales and pore sizes. Values for db varied from 0.1 to 0.6 mm, and k(L) values between 1.7 and 9.8 x 10(-4) m center dot s(-1) were determined. Several E. coli cultivations were performed in the miniature bubble column at low and high k(L)a values, and the results were compared to those from a conventional stirred tank operated under identical k(L)a values. Results from the two systems were similar in terms of biomass growth rate and carbon source utilization.
引用
收藏
页码:1175 / 1182
页数:8
相关论文
共 25 条
[1]   DESIGN OF GAS SPARGED DEVICES FOR VISCOUS-LIQUID SYSTEMS [J].
BHAVARAJU, SM ;
RUSSELL, TWF ;
BLANCH, HW .
AICHE JOURNAL, 1978, 24 (03) :454-465
[2]  
Blanch HW., 1997, BIOCH ENG, P163
[3]  
Büchs J, 2000, BIOTECHNOL BIOENG, V68, P589, DOI 10.1002/(SICI)1097-0290(20000620)68:6<589::AID-BIT1>3.0.CO
[4]  
2-J
[5]   Introduction to advantages and problems of shaken cultures [J].
Büchs, J .
BIOCHEMICAL ENGINEERING JOURNAL, 2001, 7 (02) :91-98
[6]  
CHISTI Y, 1999, ENCY BIOPROCESS TECH, V1, P2756
[7]   Evaluation of parallel operated small-scale bubble columns for microbial process development using Staphylococcus carnosus [J].
Dilsen, S ;
Paul, W ;
Herforth, D ;
Sandgathe, A ;
Altenbach-Rehm, J ;
Freudl, R ;
Wandrey, C ;
Weuster-Botz, D .
JOURNAL OF BIOTECHNOLOGY, 2001, 88 (01) :77-84
[8]   Characterisation of a novel miniaturised bubble column bioreactor for high throughput cell cultivation [J].
Doig, SD ;
Diep, A ;
Baganz, F .
BIOCHEMICAL ENGINEERING JOURNAL, 2005, 23 (02) :97-105
[9]  
DOIG SD, 2004, BASIC BIOTECHNOLOGY
[10]   Methods for intense aeration, growth, storage, and replication of bacterial strains in microtiter plates [J].
Duetz, WA ;
Rüedi, L ;
Hermann, R ;
O'Connor, K ;
Büchs, J ;
Witholt, B .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2000, 66 (06) :2641-2646