Analysis of resolution and noise properties of nonquadratically regularized image reconstruction methods for PET

被引:46
作者
Ahn, Sangtae [1 ]
Leahy, Richard M. [1 ]
机构
[1] Univ So Calif, Inst Signal & Image Proc, Los Angeles, CA 90089 USA
关键词
image resolution; noise; positron emission tomography (PET); regularization; statistical image reconstruction;
D O I
10.1109/TMI.2007.911549
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present accurate and efficient methods for estimating the spatial resolution and noise properties of non-quadratically regularized image reconstruction for positron emission tomography (PET). It is well known that quadratic regularization tends to over-smooth sharp edges. Many types of edge-preserving nonquadratic penalties have been proposed to overcome this problem. However, there has been little research on the quantitative analysis of nonquadratic regularization due to its nonlinearity. In contrast, quadratically regularized estimators are approximately linear and are well understood in terms of resolution and variance properties. We derive new approximate expressions for the linearized local perturbation response (LLPR) and variance using the Taylor expansion with the remainder term. Although the expressions are implicit, we can use them to accurately predict resolution and variance for nonquadratic regularization where the conventional expressions based on the first-order Taylor truncation fail. They also motivate us to extend the use of a certainty-based modified penalty to nonquadratic regularization cases in order to achieve spatially uniform perturbation responses, analogous to uniform spatial resolution in quadratic regularization. Finally, we develop computationally efficient methods for predicting resolution and variance of non-quadratically regularized reconstruction and present simulations that illustrate the validity of these methods.
引用
收藏
页码:413 / 424
页数:12
相关论文
共 50 条
[1]   Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms [J].
Ahn, S ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (05) :613-626
[2]  
Ahn S, 2006, I S BIOMED IMAGING, P287
[3]  
[Anonymous], 1988, Real analysis
[4]   Mean and covariance properties of dynamic PET reconstructions from list-mode data [J].
Asma, E ;
Leahy, RM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (01) :42-54
[5]   Study of relative quantification of Tc-99 m with partial volume effect and spillover correction for SPECT oncology imaging [J].
Boening, Guido ;
Pretorius, P. Hendrik ;
King, Michael A. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) :1205-1212
[6]   Covariance approximation for fast and accurate computation of channelized Hotelling observer statistics [J].
Bonetto, P ;
Qi, JY ;
Leahy, RM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) :1567-1572
[7]   A generalized Gaussian image model for edge-preserving MAP estimation [J].
Bournan, Charles ;
Sauer, Ken .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1993, 2 (03) :296-310
[8]  
BOXANDALL P, 1986, VECTOR CALCULUS
[9]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .7. A TECHNIQUE TO REDUCE NOISE IN ACCIDENTAL COINCIDENCE MEASUREMENTS AND COINCIDENCE EFFICIENCY CALIBRATION [J].
CASEY, ME ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) :845-850
[10]   Deterministic edge-preserving regularization in computed imaging [J].
Charbonnier, P ;
BlancFeraud, L ;
Aubert, G ;
Barlaud, M .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1997, 6 (02) :298-311