The use of cross-correlation analysis between high-frequency ultrasound images to measure longitudinal median nerve movement

被引:107
作者
Dilley, A
Greening, J
Lynn, B
Leary, R
Morris, V
机构
[1] UCL, Dept Physiol, London WC1E 6BT, England
[2] Univ Coll Hosp Trust, Dept Rheumatol, London, England
关键词
median nerve; speckle tracking; ultrasound; cross-correlation; carpal tunnel syndrome; biomechanics;
D O I
10.1016/S0301-5629(01)00413-6
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Impaired nerve movement can lead to nerve injury (e.g., carpal tunnel syndrome). A noninvasive method to measure nerve movement in longitudinal section would enable an extensive analysis of nerve entrapment syndromes. A method has been developed using cross-correlation between successive high-frequency ultrasound (US) images to measure longitudinal movement of nerve and muscle. Control "phantom" experiments demonstrated the accuracy and reliability of this method at velocities of 1-10 mm/s. Increasing the frame interval between the compared frames enabled the accurate calculation of slower velocities. The correlation algorithm successfully measured relative movement when the US transducer was moved 1-3 mm over the surface of the forearm. Median nerve movement was repeatedly measured in the forearm during 30 degrees passive wrist extension in three subjects (range 2.63-4.12 mm) and index finger extension in seven subjects (range 1.59-4.48 mm). Median nerve movement values were consistent with those from cadaver studies.
引用
收藏
页码:1211 / 1218
页数:8
相关论文
共 28 条
[1]   MR imaging of the carpal tunnel [J].
Allmann, KH ;
Horch, R ;
Uhl, M ;
Gufler, H ;
Altehoefer, C ;
Stark, GB ;
Langer, M .
EUROPEAN JOURNAL OF RADIOLOGY, 1997, 25 (02) :141-145
[2]   Displacement and strain of the median nerve at the wrist [J].
Bay, BK ;
Sharkey, NA ;
Szabo, RM .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1997, 22 (04) :621-627
[3]  
BERTRAND M, 1989, P IEEE ULTR S, P859
[4]   A NOVEL METHOD FOR ANGLE INDEPENDENT ULTRASONIC-IMAGING OF BLOOD-FLOW AND TISSUE MOTION [J].
BOHS, LN ;
TRAHEY, GE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (03) :280-286
[5]   TIME DOMAIN FORMULATION OF PULSE-DOPPLER ULTRASOUND AND BLOOD VELOCITY ESTIMATION BY CROSS-CORRELATION [J].
BONNEFOUS, O ;
PESQUE, P .
ULTRASONIC IMAGING, 1986, 8 (02) :73-85
[6]  
Butler DS., 1991, MOBILISATION NERVOUS
[7]   VOLUMETRIC BLOOD-FLOW VIA TIME-DOMAIN CORRELATION - EXPERIMENTAL-VERIFICATION [J].
EMBREE, PM ;
OBRIEN, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1990, 37 (03) :176-189
[8]   Reduced movement of median nerve in carpal tunnel during wrist flexion in patients with non-specific arm pain [J].
Greening, J ;
Smart, S ;
Leary, R ;
Hall-Craggs, M ;
O'Higgins, P ;
Lynn, B .
LANCET, 1999, 354 (9174) :217-218
[9]   CURRENT TIME-DOMAIN METHODS FOR ASSESSING TISSUE MOTION BY ANALYSIS FROM REFLECTED ULTRASOUND ECHOES - A REVIEW [J].
HEIN, IA ;
OBRIEN, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (02) :84-102
[10]  
HEIN IA, 1989, P IEEE ULTR S, P881