Numerical investigation of the effects of the clearance gap between the inducer and impeller of an axial blood pump

被引:9
作者
Chan, WK [1 ]
Wong, YW [1 ]
Ong, W [1 ]
Koh, SY [1 ]
Chong, V [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Prod Engn, Singapore 639798, Singapore
关键词
numerical simulation; axial blood pump; gap clearance;
D O I
10.1111/j.1525-1594.2005.29046.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A series of numerical models are generated to investigate the flow characteristics and performance of an axial blood pump. The pump model includes a straightener, an inducer-impeller, and diffuser. Numerical studies of the effects of angular alignment of the inducer and impeller blades and the axial clearance gap between the inducer and impeller are presented in this article. The pump characteristics derived from numerical simulation are validated with experimental data. Numerically simulated results showed a sinusoidal variation in the pressure generated across the pump with changes in angular alignment between the inducer and impeller. This is attributed to additional losses when flow is forced or diverted from the trailing edge of the inducer to either the pressure or suction side of the impeller blade when the alignment between the two sets of blades is not optimal. The pressure generated is a maximum when the impeller blades are at 0 or 30 degrees with respect to the inducer. The effect of rotating the impeller with respect to the inducer causes the sinusoidal pressure variation. In addition, it was observed that when the clearance gap between the inducer and impeller is reduced to 1 mm, the pressure generated is a minimum when compared to the other models. This is attributed to the interference between the inducer and impeller when the gap separating them is too small. The location of the maximum pressure on the pressure side of the impeller blade shifts upstream while its magnitude decreases for small clearance gap between the inducer and the impeller. There was no flow separation in the inducer while small regions of backflow are observed at the impeller trailing edge. Recommendations for future modifications and improvements to the pump design and model simulation are also given.
引用
收藏
页码:250 / 258
页数:9
相关论文
共 14 条
[1]  
Andrews J, 2000, ARTIF ORGANS, V24, P492
[2]  
[Anonymous], 1997, TM110446 NASA AM RES
[3]  
[Anonymous], 1995, CFX TASCFLOW VERS 2
[4]  
BARDINA JE, 1997, 28 FLUID DYN C JUN
[5]   Computational fluid dynamics performance prediction for the hydrodynamic bearings of the VentrAssist rotary blood pump [J].
Bertram, CD ;
Qian, Y ;
Reizes, JA .
ARTIFICIAL ORGANS, 2001, 25 (05) :348-357
[6]  
Coakley TJ, 1997, 28 FLUID DYN C JUN
[7]  
DAMM G, 1993, ARTIF ORGANS, V17, P609
[8]  
Hsu Cheung-Hwa, 2003, J Artif Organs, V6, P92
[9]  
Leschziner MA, 1999, P 4 INT S ENG TURB M
[10]  
Mazumdar JN, 1992, BIOFLUID MECH