Vibrational spectroscopic and ultrasound analysis for in-process characterization of high-density polyethylene/polypropylene blends during melt extrusion

被引:35
作者
Barnes, SE [1 ]
Brown, EC
Sibley, MG
Edwards, HGM
Scowen, IJ
Coates, PD
机构
[1] Univ Bradford, Sch Engn Design & Technol, IRC Polymer Sci & Technol, Bradford BD7 1DP, W Yorkshire, England
[2] Univ Bradford, Sch Life Sci, Dept Chem & Forens Sci, Bradford BD7 1DP, W Yorkshire, England
关键词
spectroscopy; Raman; near-infrared region; polymer blends; extrusion; in-line monitoring; process monitoring;
D O I
10.1366/0003702053946001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Spectroscopic techniques such as Raman, mid-infrared (MIR), and near-infrared (NIR) have become indispensable analytical tools for rapid chemical quality control and process monitoring. This paper presents the application of in-line Fourier transform near-infrared (FT-NIR) spectroscopy, Raman spectroscopy, and ultrasound transit time measurements for in-line monitoring of the composition of a series of high-density polyethylene (HDPE)/polypropylene (PP) blends during single-screw extrusion. Melt composition was determined by employing univariate analysis of the ultrasound transit time data and partial least squares (PLS) multivariate analysis of the data from both spectroscopic techniques. Each analytical technique was determined to be highly sensitive to changes in melt composition, allowing accurate prediction of blend content to within +/- 1% w/w (1 sigma) during monitoring under fixed extrusion conditions. FT-NIR was determined to be the most sensitive of the three techniques to changes in melt composition. A four-factor PLS model of the NIR blend spectra allowed determination of melt content with a standard prediction error of +/- 0.30% w/w (1 sigma). However, the NIR transmission probes employed for analysis were invasive into the melt stream, whereas the single probes adopted for Raman and ultrasound analysis were noninvasive, making these two techniques more versatile. All three measurement techniques were robust to the high temperatures and pressures experienced during melt extrusion, demonstrating each system's suitability for process monitoring and control.
引用
收藏
页码:611 / 619
页数:9
相关论文
共 38 条
[1]   In-line monitoring of polymer processing. II: Spectral data analysis [J].
Apruzzese, F ;
Reshadat, R ;
Balke, ST .
APPLIED SPECTROSCOPY, 2002, 56 (10) :1268-1274
[2]  
BAINS M, 1994, SPE ANTEC C P SOC PL, P2227
[3]  
BARNES SE, 2002, SPE ANTEC C P, P45
[4]  
BARNES SE, 2004, THESIS U BRADFORD BR
[5]  
Billmeyer F.W., 1984, TXB POLYM SCI
[6]   In line melt temperature measurement during real time ultrasound monitoring of single screw extrusion [J].
Brown, EC ;
Olley, P ;
Coates, PD .
PLASTICS RUBBER AND COMPOSITES, 2000, 29 (01) :3-13
[7]   Ultrasound: A virtual instrument approach for monitoring of polymer melt variables [J].
Brown, EC ;
Collins, TLD ;
Dawson, AJ ;
Olley, P ;
Coates, PD .
JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 1999, 18 (04) :331-338
[8]  
BROWN EC, 1998, THESIS U BRADFORD BR
[9]  
CHALMERS JM, 1993, POLYM CHARACTERIZATI
[10]   In-process vibrational spectroscopy and ultrasound measurements in polymer melt extrusion [J].
Coates, PD ;
Barnes, SE ;
Sibley, MG ;
Brown, EC ;
Edwards, HGM ;
Scowen, IJ .
POLYMER, 2003, 44 (19) :5937-5949