18F-FDG PET for mediastinal staging of lung cancer:: Which SUV threshold makes sense?

被引:161
作者
Hellwig, Dirk [1 ]
Graeter, Thomas P. [2 ,3 ]
Ukena, Dieter [4 ,5 ]
Groeschel, Andreas [4 ]
Sybrecht, Gerhard W. [4 ]
Schaefers, Hans-Joachim
Kirsch, Carl-Martin [1 ]
机构
[1] Univ Saarland, Med Ctr, Dept Nucl Med, D-66421 Homburg, Germany
[2] Univ Saarland, Med Ctr, Dept Cardiovasc & Thorac Surg, D-66421 Homburg, Germany
[3] Klin Lowenstein, Dept Thorac & Vasc Surg, Lowenstein, Germany
[4] Univ Saarland, Med Ctr, Dept Internal Med 5 Pneumol, D-6650 Homburg, Germany
[5] Klinikum Bremen Ost, Dept Pneumol, Bremen, Germany
关键词
positron emission tomography; lung neoplasms; mediastinal staging; F-18-fluorodeoxyglucose;
D O I
10.2967/jnumed.107.044362
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
F-18-FDG PET is the most accurate noninvasive modality for staging mediastinal lymph nodes in lung cancer. Besides using visual image interpretation, some institutions use standardized uptake value (SUV) measurements in lymph nodes. Mostly, an SUV of 2.5 is used as the cutoff, but this choice was never deduced from respective studies. Receiver operating characteristic (ROC) analyses demonstrated that SUV thresholds of more than 4 resulted in the highest accuracy. But these high cutoffs imply high false-negative rates (FNRs). The aim of our evaluation was to determine an optimal SUV threshold and to compare its diagnostic performance with the results of visual interpretation. Methods: This retrospective study included 95 patients with suspected lung cancer who underwent mediastinoscopy/mediastinal lymphadenectomy after F-18-FDG PET (90-150 min after 250 MBq of F-18-FDG). Maximum SUV was measured in 371 lymph node regions biopsied afterward and visually interpreted using a 6-level score (- - - through + + +). Diagnostic performance was assessed by ROC analysis. FNR and false-positive rate (FPR), the sum of both error rates (FNR + FPR), and diagnostic accuracy were plotted against a hypothetical SUV threshold to determine the optimum SUV threshold. Results: SUVs in metastatic lymph nodes were higher (mean +/- SID, 7.1 +/- 4.5; range, 1.4-26.9; n = 70) than in tumor-free lymph node stations (2.4 +/- 1.7; range, 0.6-14.9; n = 301; P < 0.01). Inflammatory lymph nodes exhibited slightly increased SUVs (2.7 +/- 2.0; range, 0.8-14.9; n = 146). The plot of error rates featured a minimum of the sum FNR + FPR for an SUV of 2.5. With increasing SUV threshold, the FPR decreased most prominently up to that value whereas a continuous rise of FNR was noticed. Highest diagnostic accuracy was achieved with an SUV of 4.5. The areas under the ROC curves demonstrated that visual interpretation tends to be more accurate than SUV quantification (visual, 0.930 +/- 0.022; SUV, 0.899 +/- 0.025; P = 0.241). Using an SUV of 2.5 as the threshold, the resulting sensitivity, specificity, and negative predictive value were 89%, 84%, and 96%, respectively. Conclusion: For mediastinal staging, the choice of an SUV of 2.5 as the threshold is justified because FNR + FPR is minimized. The resulting high negative predictive value of 96% allows the omission of mediastinoscopy in patients with negative mediastinal findings on 18F-FDG PET images. For the experienced observer, visual analysis should be relied on primarily, with calculation of the SUV used, at most, as a secondary aid. For the less experienced observer, the SUV may be of greater value.
引用
收藏
页码:1761 / 1766
页数:6
相关论文
共 34 条
[1]   Towards a minimally invasive staging strategy in NSCLC:: analysis of PET positive mediastinal lesions by EUS-FNA [J].
Annema, JT ;
Hoekstra, OS ;
Smit, EF ;
Veseliç, M ;
Versteegh, MIM ;
Rabe, KF .
LUNG CANCER, 2004, 44 (01) :53-60
[2]   BRONCHOGENIC-CARCINOMA - INCIDENCE OF METASTASES TO NORMAL SIZED LYMPH-NODES [J].
ARITA, T ;
KURAMITSU, T ;
KAWAMURA, M ;
MATSUMOTO, T ;
MATSUNAGA, N ;
SUGI, K ;
ESATO, K .
THORAX, 1995, 50 (12) :1267-1269
[3]   Is it possible TO differentiate malignant mediastinal nodes from benign nodes by size? Reevaluation by CT, transesophageal echocardiography, and nodal specimen [J].
Arita, T ;
Matsumoto, T ;
Kuramitsu, T ;
Kawamura, M ;
Matsunaga, N ;
Sugi, K ;
Esato, K .
CHEST, 1996, 110 (04) :1004-1008
[4]  
Bacsa S, 1974, Panminerva Med, V16, P402
[5]   Meta-analysis of positron emission tomographic and computed tomographic imaging in detecting mediastinal lymph node metastases in nonsmall cell lung cancer [J].
Birim, Ö ;
Kappetein, AP ;
Stijnen, T ;
Bogers, AJJC .
ANNALS OF THORACIC SURGERY, 2005, 79 (01) :375-382
[6]   Maximum standard uptake value of mediastinal lymph nodes on integrated FDG-PET-CT predicts pathology in patients with non-small cell lung cancer [J].
Bryant, Ayesha S. ;
Cerfolio, Robert J. ;
Klemm, Katrin M. ;
Ojha, Buddhiwardhan .
ANNALS OF THORACIC SURGERY, 2006, 82 (02) :417-423
[7]   Improving the inaccuracies of clinical staging of patients with NSCLC: A prospective trial [J].
Cerfolio, RJ ;
Bryant, AS ;
Ojha, B ;
Eloubeidi, M .
ANNALS OF THORACIC SURGERY, 2005, 80 (04) :1207-1214
[8]   DETECTION OF PRIMARY AND RECURRENT LUNG-CANCER BY MEANS OF F-18 FLUORODEOXYGLUCOSE POSITRON EMISSION TOMOGRAPHY (FDG PET) [J].
DUHAYLONGSOD, FG ;
LOWE, VJ ;
PATZ, EF ;
VAUGHN, AL ;
COLEMAN, RE ;
WOLFE, WG .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 110 (01) :130-140
[9]   Metastases from non-small cell lung cancer: Mediastinal staging in the 1990s - Meta-analytic comparison of PET and CT [J].
Dwamena, BA ;
Sonnad, SS ;
Angobaldo, JO ;
Wahl, RL .
RADIOLOGY, 1999, 213 (02) :530-536
[10]   Extended cervical mediastinoscopy in the staging of bronchogenic carcinoma [J].
Gilart, JF ;
García, PG ;
de Castro, FR ;
Suárez, PR ;
Rodríguez, NS ;
de Ugarte, AV .
ANNALS OF THORACIC SURGERY, 2000, 70 (05) :1641-1643