Rapid resolution of drugs and related substances with an eCAP(TM) polyamine coated capillary

被引:21
作者
Assi, KA
Altria, KD
Clark, BJ
机构
[1] UNIV BRADFORD,SCH PHARM,BRADFORD BD7 1DP,W YORKSHIRE,ENGLAND
[2] GLAXO WELLCOME RES & DEV LTD,DIV PHARMACEUT,WARE SG12 0DP,HERTS,ENGLAND
关键词
trimethoprim and related substances; drug assays; polyamine coated capillary; long-term capillary stability; method development and validation; capillary electrophoresis;
D O I
10.1016/S0731-7085(96)01993-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The long term stability of a commercial polyamine coated capillary (eCAP(TM)) is described. The capillary, which can be used in the CZE and MEKC mode, is based on coating with a polyamine after conditioning with 1 M NaOH and regeneration of this coating after each run. The stability was tested over 6 months on the drug trimethoprim and the R.S.D. values for migration time and peak area were 2.86 and 3.62% respectively (n = 8, each time of determination) (> 600 sample injections over the period). This stability was utilised in the validated method developed for trimethoprim and four of its related impurities. The repeatability of peak area for trimethoprim (without normalisation or external standard) was, within-day R.S.D. = 1.02% (n = 8) and between-days R.S.D. = 2.02% (n = 8 each day). Linearity was good (for 50 mu g ml(-1) target) (y = 249.6x + 17.3 (r = 0.992, n = 6). These results for trimethoprim and for other drug mixtures were comparison with conventional capillaries and the advantage of reducing the polyamine treated eCAP(TM) capillary to a minimum length is described, to achieve rapid assay of the 5 component timethoprim mixture in <2 min. (C) 1997 Published by Elsevier Science B.V.
引用
收藏
页码:1041 / 1049
页数:9
相关论文
共 11 条
  • [1] VALIDATED CAPILLARY ELECTROPHORESIS METHOD FOR THE ASSAY OF A RANGE OF BASIC DRUGS
    ALTRIA, KD
    FRAKE, P
    GILL, I
    HADGETT, T
    KELLY, MA
    RUDD, DR
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (08) : 951 - 957
  • [2] ALTRIA KD, 1995, CHROMATOGRAPHIA, V275, P1
  • [3] *BECKM INSTR INC, 1994, BECKM INSTR INC PUBL
  • [4] BELDER D, 1992, HRC-J HIGH RES CHROM, V15, P686
  • [5] ON-COLUMN SAMPLE CONCENTRATION USING FIELD AMPLIFICATION IN CZE
    CHIEN, RL
    BURGI, DS
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (08) : A489 - A496
  • [6] HUARY M, 1992, J MICROCOLUMN SEP, V4, P135
  • [7] HUARY M, 1992, J MICROCOLUMN SEP, V4, P233
  • [8] IMPROVEMENT OF RESOLUTION IN THE CAPILLARY ELECTROPHORETIC SEPARATION OF CATECHOLAMINES BY COMPLEX-FORMATION WITH BORIC-ACID AND CONTROL OF ELECTROOSMOSIS WITH A CATIONIC SURFACTANT
    KANETA, T
    TANAKA, S
    YOSHIDA, H
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 538 (02): : 385 - 391
  • [9] KELLY MA, 1996, IN PRESS CHROMATOGRA
  • [10] MOSELEY MA, 1991, ANAL CHEM, V63, P1109