Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: Preliminary experience

被引:263
作者
Meaney, JFM
Ridgway, JP
Chakraverty, S
Robertson, I
Kessel, D
Radjenovic, A
Kouwenhoven, M
Kassner, A
Smith, MA
机构
[1] Leeds Gen Infirm, Dept Magnet Resonance, Leeds LS2 1EX, W Yorkshire, England
[2] Leeds Gen Infirm, Dept Phys Med, Leeds LS2 1EX, W Yorkshire, England
[3] Bradford Royal Infirm, Dept Radiol, Leeds, W Yorkshire, England
[4] St James Univ Hosp, Dept Radiol, Leeds LS9 7TF, W Yorkshire, England
[5] Philips Med Syst, Best, Netherlands
关键词
D O I
10.1148/radiology.211.1.r99ap1859
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare stepping-table digital subtraction gadolinium-enhanced magnetic resonance (MR) angiography of the distal aorta and lower extremity arteries with conventional catheter digital subtraction x-ray angiography in patients with arterio-occlusive disease. MATERIALS AND METHODS: Twenty patients underwent both conventional catheter angiography and fast three-dimensional gadolinium-enhanced MR angiography of the aorta and outflow vessels at 1.5 T; the images were acquired in three consecutive imaging locations during a single infusion of a gadolinium chelate. RESULTS: Compared with catheter angiography, according to the findings of two blinded independent reviewers, MR angiography had sensitivities of 81% and 89% and specificities of 91% and 95%, respectively, for demonstration of insignificant (less than or equal to 50%) stenosis versus significant (51%-100%) stenosis. For demonstration of occlusion, the sensitivity and specificity were 94% and 97%, respectively, by consensus. There was good interobserver correlation between the two readers overall (kappa = 0.65 for reporting the degree of narrowing in all lesions; 0.86, for reporting of insignificant versus significant stenoses; and 0.928, for reporting of occluded versus patent segments). CONCLUSION: Stepping-table digital subtraction contrast material-enhanced MR angiography has high accuracy compared with catheter angiography in patients with arterio-occlusive disease of the aorta and outflow vessels, these preliminary, study results suggest that this technique may ultimately provide a safe, noninvasive, and cost-effective alternative to catheter angiography.
引用
收藏
页码:59 / 67
页数:9
相关论文
共 32 条
  • [1] MR-ANGIOGRAPHY VERSUS CONVENTIONAL X-RAY ANGIOGRAPHY IN THE LOWER-EXTREMITIES - EVERYONE WINS
    BORRELLO, JA
    [J]. RADIOLOGY, 1993, 187 (03) : 615 - 617
  • [2] Bron KM, 1983, ABRAMS ANGIOGRAPHY V, P1835
  • [3] PERIPHERAL VASCULAR-SURGERY WITH MAGNETIC-RESONANCE ANGIOGRAPHY AS THE SOLE PREOPERATIVE IMAGING MODALITY
    CARPENTER, JP
    BAUM, RA
    HOLLAND, GA
    BARKER, CF
    WILKERSON, D
    ODONNELL, TF
    BERKOWITZ, HD
    RICOTTA, JR
    [J]. JOURNAL OF VASCULAR SURGERY, 1994, 20 (06) : 861 - 871
  • [4] FAST MR-ANGIOGRAPHY OF THE AORTOILIAC ARTERIES AND ARTERIES OF THE LOWER-EXTREMITY - VALUE OF BOLUS-ENHANCED, WHOLE-VOLUME SUBTRACTION TECHNIQUE
    DOUEK, PC
    REVEL, D
    CHAZEL, S
    FALISE, B
    VILLARD, J
    AMIEL, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 431 - 437
  • [5] REDUCTION OF PARTIAL-VOLUME ARTIFACTS WITH ZERO-FILLED INTERPOLATION IN 3-DIMENSIONAL MR-ANGIOGRAPHY
    DU, YPP
    PARKER, DL
    DAVIS, WL
    CAO, G
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05): : 733 - 741
  • [6] Cardiac-gated MR angiography of the entire lower extremity: A prospective comparison with conventional angiography
    Glickerman, DJ
    Obregon, RG
    Schmiedl, UP
    Harrison, SD
    Macaulay, SE
    Simon, HE
    Kohler, TR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) : 445 - 451
  • [7] MR angiography of the iliac and upper femoral arteries using four different inflow techniques
    Ho, KY
    deHaan, MW
    Oei, TK
    Koster, D
    Kessels, AGH
    Janevski, BK
    Kitslaar, P
    vanEngelshoven, JMA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (01) : 45 - 53
  • [8] REAL-TIME INTERACTIVE MAGNETIC-RESONANCE-IMAGING
    HOLSINGER, AE
    WRIGHT, RC
    RIEDERER, SJ
    FARZANEH, F
    GRIMM, RC
    MAIER, JK
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (03) : 547 - 553
  • [9] LOWER-EXTREMITIES - MR-ANGIOGRAPHY WITH A UNILATERAL TELESCOPIC PHASED-ARRAY COIL
    KOJIMA, KY
    SZUMOWSKI, J
    SHELEY, RC
    QUINN, SF
    [J]. RADIOLOGY, 1995, 196 (03) : 871 - 875
  • [10] DIAGNOSTIC PERFORMANCE OF DIGITAL SUBTRACTION ANGIOGRAPHY (DSA) AND MAGNETIC-RESONANCE ANGIOGRAPHY (MRA) - PRELIMINARY-RESULTS IN VASCULAR OCCLUSIVE DISEASE OF THE ABDOMINAL AND LOWER-EXTREMITY ARTERIES
    KRUG, B
    KUGEL, H
    HARNISCHMACHER, U
    HEINDEL, W
    FISCHBACH, R
    ALTENBURG, A
    KRINGS, F
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1995, 19 (02) : 77 - 85