A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 1)

被引:67
作者
Poscia, A
Mascini, M
Moscone, D
Luzzana, M
Caramenti, G
Cremonesi, P
Valgimigli, F
Bongiovanni, C
Varalli, M
机构
[1] A Menarini Ind Farmaceut Riunite Srl, Dept Res & Dev, I-50131 Florence, Italy
[2] Univ Florence, Dipartimento Chim, I-50019 Sesto Fiorentino, FI, Italy
[3] Univ Milan, Dipartimento Sci & Tecnol Biomed, I-20090 Milan, Italy
[4] CNR, Ist Tecnol Biomed, I-20090 Milan, Italy
[5] Univ Roma Tor Vergata, INFM, I-00133 Rome, Italy
[6] Univ Roma Tor Vergata, Dipartimento Biol, I-00133 Rome, Italy
[7] Univ Roma Tor Vergata, Dipartimento Sci & Tecnol Chim, I-00133 Rome, Italy
关键词
biosensors; continuous monitoring; glucose; microdialysis;
D O I
10.1016/S0956-5663(02)00216-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The performances and the stability of a novel subcutaneous glucose monitoring system have been evaluated. GlucoDay(R) (A. Menarini I.F.R. S.r.l, Florence Italy) is a portable instrument provided with a micro-pump and a biosensor coupled to a microdialysis system capable of recording the subcutaneous glucose level every 3 min. Long and short term stability of the biosensor are discussed and the results of some critical in vitro and in vivo (on rabbits) experiments are reported. A linear response up to 30 mM has been found for in vivo glucose concentration. The sensitivity referred to blood glucose is better than 0.1 mM and the zero current is typically below the equivalent of 0.1 mM. In the accuracy study a mean bias of 2.7 mg/dl and a correlation coefficient equal to 0.9697 have been found. At room temperature, an excellent membrane stability assures good performances up to 6 months from the first use. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:891 / 898
页数:8
相关论文
共 18 条
[1]  
ALCOCK SJ, 1996, PROSPECTS IN VIVO SE
[2]   Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring [J].
Aussedat, B ;
Dupire-Angel, M ;
Gifford, R ;
Klein, JC ;
Wilson, GS ;
Reach, G .
AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2000, 278 (04) :E716-E728
[3]   EFFECTS OF CHRONIC ELEVATION IN PLASMA-CORTISOL ON HEPATIC CARBOHYDRATE-METABOLISM [J].
GOLDSTEIN, RE ;
WASSERMAN, DH ;
MCGUINNESS, OP ;
LACY, DB ;
CHERRINGTON, AD ;
ABUMRAD, NN .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 264 (01) :E119-E127
[4]   INVIVO MICRODIALYSIS AS A TECHNIQUE TO MONITOR DRUG TRANSPORT - CORRELATION OF EXTRACELLULAR COCAINE LEVELS AND DOPAMINE OVERFLOW IN THE RAT-BRAIN [J].
HURD, YL ;
KEHR, J ;
UNGERSTEDT, U .
JOURNAL OF NEUROCHEMISTRY, 1988, 51 (04) :1314-1316
[5]   THE FUNCTION OF A HYDROGEN PEROXIDE-DETECTING ELECTROENZYMATIC GLUCOSE ELECTRODE IS MARKEDLY IMPAIRED IN HUMAN SUB-CUTANEOUS TISSUE AND PLASMA [J].
KERNER, W ;
KIWIT, M ;
LINKE, B ;
KECK, FS ;
ZIER, H ;
PFEIFFER, EF .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (9-10) :473-482
[6]  
Mastrototaro J, 1999, J PEDIATR ENDOCR MET, V12, P751
[7]   SUBCUTANEOUS MICRODIALYSIS PROBE COUPLED WITH GLUCOSE BIOSENSOR FOR INVIVO CONTINUOUS MONITORING [J].
MOSCONE, D ;
PASINI, M ;
MASCINI, M .
TALANTA, 1992, 39 (08) :1039-1044
[8]  
MOSCONE D, 1993, ANALUSIS, V21, pM40
[9]  
MOSCONE D, 1993, IN VIVO MONITORING M, P115
[10]   Detection of hypoglycemia with the GlucoWatch biographer [J].
Pitzer, KR ;
Desai, S ;
Dunn, T ;
Edelman, S ;
Jayalakshmi, Y ;
Kennedy, J ;
Tamada, JA ;
Potts, RO .
DIABETES CARE, 2001, 24 (05) :881-885