Local mechanical anisotropy in human cranial dura mater allografts

被引:25
作者
Sacks, MS [1 ]
Hamann, MCJ
Otano-Lata, SE
Malinin, TI
机构
[1] Univ Miami, Dept Biomed Engn, Coral Gables, FL 33124 USA
[2] Univ Miami, Dept Orthopaed & Rehabil, Coral Gables, FL 33124 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 1998年 / 120卷 / 04期
关键词
D O I
10.1115/1.2798027
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Human cranial dura mater (CDM) allograft's success as a repair biomaterial is partly due to its high mechanical strength, which facilitates its ability to form water-tight barriers and resist high in-vivo mechanical lends. Previous studies on CDM allograft mechanical behavior used large test specimens and concluded that the allograft was mechanically isotropic. However, we have quantified CDM microstructure using small angle light scattering (SALS) and found regions of well-aligned fibers displaying structural symmetry between the right and left halves (Jimenez et al., 1998). The high degree of fiber alignment in these regions suggests that they are mechanically anisotropic. However, identification of these regions using SALS requires irreversible tissue dehydration, which may affect mechanical propel-ties. Instead, we utilized CDM structural symmetry to estimate the fiber architecture of one half of the CDM using computer graphics to flip the SALS fiber architecture map of the corresponding half about the plane of symmetry. Test specimens (20 mm x 4 mm) were selected parallel and perpendicular to the preferred fiber directions and subjected to uniaxial mechanical failure testing. CDM allografts were found to be locally anisotropic, having an ultimate tensile strength (UTS) parallel to the fibers of 12.76 +/- 1.65 MPa, and perpendicular to the fibers of 5.21 +/- 1.01 MPa (mean +/- sem). These results indicate that uniaxial mechanical tests on large samples used in previous studies tended to mask the local anisotropic nature of the smaller constituent sections. The testing methods established in this study can be used in the evaluation of new CDM processing methods and post-implant allograft mechanical integrity.
引用
收藏
页码:541 / 544
页数:4
相关论文
共 21 条
[1]
CLINICAL USE OF FREEZE-DRIED HUMAN DURA MATER [J].
CAMPBELL, JB ;
BASSETT, CAL ;
ROBERTSON, JW .
JOURNAL OF NEUROSURGERY, 1958, 15 (02) :207-214
[2]
ON THE ANISOTROPY OF THE CANINE DIAPHRAGMATIC CENTRAL TENDON [J].
CHUONG, CJ ;
SACKS, MS ;
JOHNSON, RL ;
REYNOLDS, R .
JOURNAL OF BIOMECHANICS, 1991, 24 (07) :563-&
[3]
FEMORAL VESSEL COVERAGE WITH DURA-MATER AFTER INGUINOFEMORAL LYMPHADENECTOMY [J].
FIORICA, JV ;
ROBERTS, WS ;
LAPOLLA, JP ;
HOFFMAN, MS ;
BARTON, DPJ ;
CAVANAGH, D .
GYNECOLOGIC ONCOLOGY, 1991, 42 (03) :217-221
[4]
TREATMENT OF PERIODONTAL FURCATION DEFECTS - CORONALLY POSITIONED FLAPS VERSUS DURA MATER MEMBRANES IN CLASS-2 DEFECTS [J].
GARRETT, S ;
MARTIN, M ;
EGELBERG, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1990, 17 (03) :179-185
[5]
Jimenez Hamann Maria C., 1998, Journal of Anatomy, V192, P99, DOI 10.1046/j.1469-7580.1998.19210099.x
[7]
USE OF ADHESIVE AND LYOPHILIZED DURA IN TREATMENT OF CEREBROSPINAL RHINORRHEA - TECHNICAL NOTE [J].
LEHMAN, RAW ;
HAYES, GJ ;
MARTINS, AN .
JOURNAL OF NEUROSURGERY, 1967, 26 (1P1) :92-&
[8]
MECHANICAL SUITABILITY OF GLYCEROL-PRESERVED HUMAN DURA MATER FOR CONSTRUCTION OF PROSTHETIC CARDIAC VALVES [J].
MCGARVEY, KA ;
LEE, JM ;
BOUGHNER, DR .
BIOMATERIALS, 1984, 5 (02) :109-117
[9]
MELVIN JW, 1970, P 14 STAPP CAR CRASH, V17, P221
[10]
OTANO SE, 1995, P 1995 BIOENG C, V29, P329