Increased sensitivity in neuroimaging analyses using robust regression

被引:228
作者
Wager, TD
Keller, MC
Lacey, SC
Jonides, J
机构
[1] Columbia Univ, Dept Psychol, New York, NY 10027 USA
[2] Univ Michigan, Dept Psychol, Ann Arbor, MI 48109 USA
关键词
D O I
10.1016/j.neuroimage.2005.01.011
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Robust regression techniques are a class of estimators that are relatively insensitive to the presence of one or more outliers in the data. They are especially well suited to data that require large numbers of statistical tests and may contain outliers due to factors not of experimental interest. Both these issues apply particularly to neuroimaging data analysis. We use simulations to compare several robust techniques against ordinary least squares (OLS) regression, and we apply robust regression to second-level (group "random effects") analyses in three fMRI datasets. Our results show that robust iteratively reweighted least squares (IRLS) at the 2nd level is a computationally efficient technique that both increases statistical power and decreases false positive rates in the presence of outliers. The benefits of IRLS are apparent with small samples (n = 10) and increase with larger sample sizes (n = 40) in the typical range of group neuroirnaging experiments. When no true effects are present, IRLS controls false positive rates at an appropriate level. We show that IRLS can have substantial benefits in analysis of group data and in estimating hemodynamic response shapes from time series data. We provide software to implement IRLS in group neuroimaging analyses. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:99 / 113
页数:15
相关论文
共 51 条
[1]  
Ashburner J, 1999, HUM BRAIN MAPP, V7, P254, DOI 10.1002/(SICI)1097-0193(1999)7:4<254::AID-HBM4>3.0.CO
[2]  
2-G
[3]   Reward circuitry activation by noxious thermal stimuli [J].
Becerra, L ;
Breiter, HC ;
Wise, R ;
Gonzalez, RG ;
Borsook, D .
NEURON, 2001, 32 (05) :927-946
[4]  
Büchel C, 1999, SCIENCE, V283, P1538, DOI 10.1126/science.283.5407.1538
[5]   Unsupervised robust nonparametric estimation of the hemodynamic response function for any fMRI experiment [J].
Ciuciu, P ;
Poline, JB ;
Marrelec, G ;
Idier, J ;
Pallier, C ;
Benali, H .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (10) :1235-1251
[6]   Event-related fMRI of pain: entering a new era in imaging pain [J].
Davis, KD ;
Kwan, CL ;
Crawley, AP ;
Mikulis, DJ .
NEUROREPORT, 1998, 9 (13) :3019-3023
[7]  
DUMOUCHEL WH, 1989, P 21 S INT AM STAT A
[8]  
FRANCKE L, 1993, SIGHT SOUND, V3, P30
[9]   Estimation of respiration-induced noise fluctuations from undersampled multislice fMRI data [J].
Frank, LR ;
Buxton, RB ;
Wong, EC .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :635-644
[10]   CHARACTERIZING EVOKED HEMODYNAMICS WITH FMRI [J].
FRISTON, KJ ;
FRITH, CD ;
TURNER, R ;
FRACKOWIAK, RSJ .
NEUROIMAGE, 1995, 2 (02) :157-165