Electro-chemical deposition of nano hydroxyapatite-zinc coating on titanium metal substrate

被引:25
作者
El-Wassefy, N. A. [1 ]
Reicha, F. M. [2 ]
Aref, N. S. [1 ]
机构
[1] Mansoura Univ, Dent Biomat Dept, Fac Dent, 35516 El Gomhoria St, Mansoura, Egypt
[2] Mansoura Univ, Phys Dept, Fac Sci, 35516 El Gomhoria St, Mansoura, Egypt
关键词
Hydroxyapatite-zinc coating; Titanium metal; Surface roughness; Surface morphology; Coating adhesion; Electrochemical deposition; IMPLANTS; ELECTRODEPOSITION; BIOFILMS; INHIBITION; SURFACES; GROWTH; TIO2;
D O I
10.1186/s40729-017-0095-1
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Titanium is an inert metal that does not induce osteogenesis and has no antibacterial properties; it is proposed that hydroxyapatite coating can enhance its bioactivity, while zinc can contribute to antibacterial properties and improve osseointegration. A nano-sized hydroxyapatite-zinc coating was deposited on commercially pure titanium using an electro-chemical process, in order to increase its surface roughness and enhance adhesion properties. The hydroxyapatite-zinc coating was attained using an electro-chemical deposition in a solution composed of a naturally derived calcium carbonate, di-ammonium hydrogen phosphate, with a pure zinc metal as the anode and titanium as the cathode. The applied voltage was -2.5 for 2 h at a temperature of 85 A degrees C. The resultant coating was characterized for its surface morphology and chemical composition using a scanning electron microscope (SEM), energy dispersive x-ray spectroscope (EDS), and Fourier transform infrared (FT-IR) spectrometer. The coated specimens were also evaluated for their surface roughness and adhesion quality. Hydroxyapatite-zinc coating had shown rosette-shaped, homogenous structure with nano-size distribution, as confirmed by SEM analysis. FT-IR and EDS proved that coatings are composed of hydroxyapatite (HA) and zinc. The surface roughness assessment revealed that the coating procedure had significantly increased average roughness (Ra) than the control, while the adhesive tape test demonstrated a high-quality adhesive coat with no laceration on tape removal. The developed in vitro electro-chemical method can be employed for the deposition of an even thickness of nano HA-Zn adhered coatings on titanium substrate and increases its surface roughness significantly.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 32 条
[1]
Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies [J].
Abu-Amer, Yousef ;
Darwech, Isra ;
Clohisy, John C. .
ARTHRITIS RESEARCH & THERAPY, 2007, 9 (Suppl 1)
[2]
Battistella E, 2010, ADV MAT RES, V89-91, P47
[3]
Substantivity of zinc salts used as rinsing solutions and their effect on the inhibition of Streptococcus mutans [J].
Burguera-Pascu, Margarita ;
Rodriguez-Archilla, Alberto ;
Baca, Pilar .
JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2007, 21 (02) :92-101
[4]
Our Midterm Results of the Birmingham Hip Resurfacing With and Without Navigation [J].
El Hachmi, Mohamed ;
Penasse, Michel .
JOURNAL OF ARTHROPLASTY, 2014, 29 (04) :808-812
[5]
Influence of thickness on the properties of hydroxyapatite coatings deposited by KrF laser ablation [J].
Fernández-Pradas, JM ;
Clèries, L ;
Martínez, E ;
Sardin, G ;
Esteve, J ;
Morenza, JL .
BIOMATERIALS, 2001, 22 (15) :2171-2175
[6]
Effect of the particle size on the micro and nanostructural features of a calcium phosphate cement: a kinectic analysis [J].
Ginebra, MP ;
Driessens, FCM ;
Planell, JA .
BIOMATERIALS, 2004, 25 (17) :3453-3462
[7]
Influence of the zinc concentration of sol-gel derived zinc substituted hydroxyapatite on cytokine production by human monocytes in vitro [J].
Grandjean-Laquerrier, A ;
Laquerriere, P ;
Jallot, E ;
Nedelec, JM ;
Guenounou, M ;
Laurent-Maquin, D ;
Phillips, TM .
BIOMATERIALS, 2006, 27 (17) :3195-3200
[8]
Effects of zinc on human skeletal alkaline phosphatase activity in vitro [J].
Hall, SL ;
Dimai, HP ;
Farley, JR .
CALCIFIED TISSUE INTERNATIONAL, 1999, 64 (02) :163-172
[9]
Heydenrijk K, 2002, INT J ORAL MAX IMPL, V17, P829
[10]
Holister P., 2003, Cientifica, V3, P1