Performance of cryogenic microbolometers and calorimeters with on-chip coolers

被引:20
作者
Anghel, DV [1 ]
Luukanen, A [1 ]
Pekola, JP [1 ]
机构
[1] Univ Jyvaskyla, Dept Phys, FIN-40351 Jyvaskyla, Finland
关键词
D O I
10.1063/1.1339261
中图分类号
O59 [应用物理学];
学科分类号
摘要
Astronomical observations of cosmic sources in the far-infrared and x-ray bands require extreme sensitivity. The most sensitive detectors are cryogenic bolometers and calorimeters operating typically at about 100 mK. The last stage of cooling (from 300 to 100 mK) often poses significant difficulties in space-borne experiments, both in system complexity and in reliability. We address the possibility of using refrigeration based on normal metal/insulator/superconductor (NIS) tunnel junctions as the last stage cooler for cryogenic thermal detectors. We compare two possible schemes: direct cooling of the electron gas of the detector with the aid of NIS tunnel junctions and the indirect cooling method, when the detector lattice is cooled by the refrigerating system, while the electron gas temperature is decreased by electron-phonon interaction. The latter method is found to allow at least an order of magnitude improvement in detector noise equivalent power compared to direct electron cooling. (C) 2001 American Institute of Physics.
引用
收藏
页码:556 / 558
页数:3
相关论文
共 16 条
[1]  
ANGHEL DV, UNPUB J LOW TEMP PHY
[2]  
ANGHEL DV, 2000, THESIS U JYVASKYLA
[3]  
[Anonymous], 1996, MATTER METHODS LOW T
[4]   The X-ray Evolving Universe Spectroscopy mission (XEUS) [J].
Bavdaz, M ;
Bleeker, JAM ;
Hasinger, G ;
Inoue, H ;
Palumbo, G ;
Peacock, A ;
Parmar, A ;
Turner, MJ ;
Truemper, J ;
Schiemann, J .
X-RAY OPTICS, INSTRUMENTS, AND MISSIONS II, 1999, 3766 :82-93
[5]   High-power on-chip microrefrigerator based on a normal-metal/insulator/superconductor tunnel junction [J].
Fisher, PA ;
Ullom, JN ;
Nahum, M .
APPLIED PHYSICS LETTERS, 1999, 74 (18) :2705-2707
[6]  
Glowala S. R., 1997, Proc. of the 7th International Workshop on Low Temperature Detectors, P64
[7]  
GOLUBEV D, 1999, ANDREEV REFLECTION I
[8]   X-ray detection using a superconducting transition-edge sensor microcalorimeter with electrothermal feedback [J].
Irwin, KD ;
Hilton, GC ;
Wollman, DA ;
Martinis, JM .
APPLIED PHYSICS LETTERS, 1996, 69 (13) :1945-1947
[9]   A superconducting bolometer with strong electrothermal feedback [J].
Lee, AT ;
Richards, PL ;
Nam, SW ;
Cabrera, B ;
Irwin, KD .
APPLIED PHYSICS LETTERS, 1996, 69 (12) :1801-1803
[10]   Efficient Peltier refrigeration by a pair of normal metal/insulator/superconductor junctions [J].
Leivo, MM ;
Pekola, JP ;
Averin, DV .
APPLIED PHYSICS LETTERS, 1996, 68 (14) :1996-1998