Improved multiplex immunoassay performance in human plasma and synovial fluid following removal of interfering heterophilic antibodies

被引:205
作者
de Jager, W
Prakken, BJ
Bijlsma, JWJ
Kuis, W
Rijkers, GT
机构
[1] Univ Utrecht, Med Ctr, Dept Pediat Immunol, Wilhelmina Childrens Hosp, Utrecht, Netherlands
[2] Univ Utrecht, Med Ctr, Dept Rheumatol & Clin Immunol, Utrecht, Netherlands
[3] IACOPO, Inst Translat Med, La Jolla, CA USA
关键词
multiplex immunoassay; luminex; protein-L; rheumatoid factor; cytokines;
D O I
10.1016/j.jim.2005.03.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cytokines, chemokines and soluble adhesion molecules interact in a complex network within the immune system. Fingerprinting of these proteins may allow the use of these proteins as biomarkers for identification of disease, disease subtyping and monitoring therapeutic interventions. We developed a multiplex immunoassay (MIA) for the detection of 30 proteins in a variety of human body fluids such as plasma and synovial fuid (SF). The measurement of these proteins is hampered by the presence of human (auto-) antibodies, which can cause non-specific binding. We have validated a novel approach for the removal of interfering immunoglobulins using pre-absorption with protein-L. Interfering (auto-) antibodies, such as rheumatoid factor (RF), were removed using three methods; polyethylene glycol (PEG) precipitation, pre-absorption with human gamma-globulin or pre-absorption with protein-L. A significant decrease of RF was observed after a 2 h incubation with protein-L. RF IgM levels were reduced by 89% whereas total IgM, IgG and IgA levels were reduced by 60%. Residual immunoglobulins were blocked with rodent serum and did not interfere with the multiplex immunoassay. Comparing the MIA with a conventional enzyme-linked immunosorbent assay (ELISA) using a panel of spiked plasma samples resulted in correlation coefficients for all mediators between R-2 = 0.88 and R-2=0.99. Intra-assay variance was less than 10% whereas inter-assay variance ranged between 6% and 16%. Pathological samples with heterophilic antibodies hamper immunoassays such as ELISA and MIA. We show that preabsorption with protein-L is a powerful tool for removal of interfering immunoglobulins from human bodily fluids to be used in immunoassays for studying changes in protein patterns. (c) 2005 Elsevier B.V All rights reserved.
引用
收藏
页码:124 / 135
页数:12
相关论文
共 23 条
  • [1] AKERSTROM B, 1989, J BIOL HCEM, P19740
  • [2] Advances in immunology - Autoimmune diseases
    Davidson, A
    Diamond, B
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (05) : 340 - 350
  • [3] Simultaneous detection of 15 human cytokines in a single sample of stimulated peripheral blood mononuclear cells
    de Jager, W
    te Velthuis, H
    Prakken, BJ
    Kuis, W
    Rijkers, GT
    [J]. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2003, 10 (01) : 133 - 139
  • [4] Antinuclear antibodies following infliximab treatment in patients with rheumatoid arthritis or spondylarthropathy
    De Rycke, L
    Kruithof, E
    Van Damme, N
    Hoffman, IEA
    Van den Bossche, N
    Van den Bosch, F
    Veys, EM
    De Keyser, F
    [J]. ARTHRITIS AND RHEUMATISM, 2003, 48 (04): : 1015 - 1023
  • [5] REPEATED THERAPY WITH MONOCLONAL-ANTIBODY TO TUMOR-NECROSIS-FACTOR-ALPHA (CA2) IN PATIENTS WITH RHEUMATOID-ARTHRITIS
    ELLIOTT, MJ
    MAINI, RN
    FELDMANN, M
    LONGFOX, A
    CHARLES, P
    BIJL, H
    WOODY, JN
    [J]. LANCET, 1994, 344 (8930) : 1125 - 1127
  • [6] Fleishmann RM, 2002, CLIN EXP RHEUMATOL, V20, pS35
  • [7] Chemokines in autoimmune disease
    Godessart, N
    Kunkel, SL
    [J]. CURRENT OPINION IN IMMUNOLOGY, 2001, 13 (06) : 670 - 675
  • [8] The influence of naturally occurring heterophilic anti-immunoglobulin antibodies on direct measurement of serum proteins using sandwich ELISAs
    Hennig, C
    Rink, L
    Fagin, U
    Jabs, WJ
    Kirchner, H
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 235 (1-2) : 71 - 80
  • [9] Kellar KL, 2001, CYTOMETRY, V45, P27, DOI 10.1002/1097-0320(20010901)45:1<27::AID-CYTO1141>3.0.CO
  • [10] 2-I