Stereolithographic (SL) biomodelling in craniofacial surgery

被引:33
作者
D'Urso, PS [1 ]
Atkinson, RL
Lanigan, MW
Earwaker, WJ
Bruce, IJ
Holmes, A
Barker, TM
Effeney, DJ
Thompson, RG
机构
[1] Univ Queensland, Dept Surg, Brisbane, Qld 4072, Australia
[2] Univ Queensland, Mater Childrens Hosp, Craniofacial Clin, Brisbane, Qld 4101, Australia
[3] Holy Spirit Hosp, Dept Diagnost Imaging, Brisbane, Qld, Australia
[4] Royal Childrens Hosp, Melbourne Craniofacial Unit, Melbourne, Vic, Australia
[5] Queensland Univ Technol, Sch Mech Mfg & Med Engn, Brisbane, Qld, Australia
[6] Queensland Mfg Inst, Brisbane, Qld, Australia
来源
BRITISH JOURNAL OF PLASTIC SURGERY | 1998年 / 51卷 / 07期
关键词
D O I
10.1054/bjps.1998.0026
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Stereolithographic (SL) biomodelling allows 3D CT to be used to generate solid plastic replicas of anatomical structures (biomodels). Case reports in the literature suggest that such biomodels may have a use in craniofacial surgery but no large series or assessment of utility has been reported. A prospective trial to assess the utility of biomodeiling in craniofacial surgery has been performed. Methods: Forty patients with complex craniofacial abnormalities were selected and 3D CT scanning performed. The data of interest was used to guide a laser to selectively polymerise photosensitive resin to manufacture SL biomodels. The biomodels were used for patient education, diagnosis and operative planning. An assessment protocol was designed to test the hypothesis that biomodels in addition to standard imaging had greater utility in the surgery performed than the standard imaging alone. Results: Anecdotally surgeons found biomodelling useful in 40 complex craniofacial operations. The formal assessment of the first 10 cases suggested biomodels improved operative planning (image 76%, image with bio-model 97%, P < 0.01) and diagnosis (image 82.5%, image with biomodel 99.25%, P < 0.01). Surgeons estimated that the use of biomodels had reduced operating time by a mean of 16% and were cost effective at a mean price of $1100 AUS. Conclusion: Biomodelling was reported as an intuitive, user-friendly technology that facilitated diagnosis, operative planning and communication between colleagues and patients. Limitations of the technology were manufacturing time and cost.
引用
收藏
页码:522 / 530
页数:9
相关论文
共 37 条
[1]  
Abbott J., 1994, AUST J OTOLARYNGOL, V1, P581
[2]   MAXILLOFACIAL BIOMODELLING [J].
ARVIER, JF ;
BARKER, TM ;
YAU, YY ;
DURSO, PS ;
ATKINSON, RL ;
MCDERMANT, GR .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1994, 32 (05) :276-283
[3]   STEREOLITHOGRAPHY IN ORAL AND MAXILLOFACIAL OPERATION PLANNING [J].
BILL, JS ;
REUTHER, JF ;
DITTMANN, W ;
KUBLER, N ;
MEIER, JL ;
PISTNER, H ;
WITTENBERG, G .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1995, 24 (01) :98-103
[4]   3-DIMENSIONAL COMPUTER-ASSISTED DESIGN OF CRANIOFACIAL SURGICAL-PROCEDURES - OPTIMIZATION AND INTERACTION WITH CEPHALOMETRIC AND CT-BASED MODELS [J].
CUTTING, C ;
BOOKSTEIN, FL ;
GRAYSON, B ;
FELLINGHAM, L ;
MCCARTHY, JG .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1986, 77 (06) :877-885
[5]  
CUTTING C, 1986, CLIN PLAST SURG, V13, P449
[6]  
David DJ., 1990, CRANIOFACIAL DEFORMI
[7]  
Fujioka M, 1988, Radiat Med, V6, P204
[8]  
FUKUTA K, 1990, European Journal of Plastic Surgery, V13, P209
[9]  
FUKUTA K, 1992, PERSPECT PLAST SURG, V6, P155
[10]   Validation of the EORTC QLQ-C30 quality of life questionnaire through combined qualitative and quantitative assessment of patient-observer agreement [J].
Groenvold, M ;
Klee, MC ;
Sprangers, MAG ;
Aaronson, NK .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1997, 50 (04) :441-450