Mandibulotomy fixation: A laboratory analysis

被引:12
作者
Engroff, SL
Blanchaert, RH
von Fraunhofer, JA
机构
[1] Tri Cty Oral Facial Surg, State Coll, PA USA
[2] Univ Missouri, Sch Med, Kansas City, MO 64108 USA
[3] Univ Missouri, Sch Dent, Truman Med Ctr, Kansas City, MO 64108 USA
[4] Univ Maryland, Baltimore Coll Dent Surg, Sch Dent, Baltimore, MD 21201 USA
关键词
D O I
10.1016/S0278-2391(03)00731-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Mandibulotomy is an access osteotomy technique associated with significant complications. Critical evaluation of available fixation systems is required to aid in the selection of the most stable fixation method. This study was designed to provide data on the stability of traditionally used plating configurations and a low-profile 2.0-mm locking plate (mandibular locking plate, Synthes MLP; Synthes Maxillofacial, Paoli, PA). Materials and Methods: An in vitro red oak model was used to evaluate the stability provided by the study fixation devices. Five groups were studied as follows: group 1, two 4-hole 2.0-mm nonlocking miniplates; group 2, two 4-hole 2.0-mm mandibular locking plates; group 3, one 6-hole 2.0-mm mandibular locking plate; group 4, one 6-hole 2.4-mm nonlocking rigid plate; and group 5, control (uncut red oak blocks). Each specimen was tested with vertical loads applied over the osteotomy site. The force-versus-displacement behavior was recorded for each specimen and analyzed statistically. Results: Plate type and configuration affected the resistance to vertical peak load (kilogram/force [kgf]) and the fixation stiffness (kgf/mm). The greatest peak load (58.92 kgf) and stiffness (7.07 kgf/mm) was found with group 2 specimens. The differences in system stiffness were statistically significant (P < .05), as were the peak loads for groups 1, 2, and 3. The control group (nonosteotomized red oak) had markedly higher values of peak load and stiffness (484 kg and 83 kg/mm, respectively). Group 2 specimens exhibited increased resistance to flexion. Conclusions: Two 2.0-mm locking plates provided the greatest resistance to vertical load. (C) 2003 American Association of Oral and Maxillofacial Surgeons.
引用
收藏
页码:1297 / 1301
页数:5
相关论文
共 18 条
[1]   Non-union of mandibulotomy sites following irradiation for squamous cell carcinoma of the oral cavity [J].
Altman, K ;
Bailey, BMW .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1996, 34 (01) :62-65
[2]   Straight midline mandibulotomy revisited [J].
Amin, MR ;
Deschler, DG ;
Hayden, RE .
LARYNGOSCOPE, 1999, 109 (09) :1402-1405
[3]  
Ashman R B, 1987, Adv Dent Res, V1, P64
[4]   Substitutes for human cadaveric hone in maxillofacial rigid fixation research [J].
Bredbenner, TL ;
Haug, RH .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2000, 90 (05) :574-580
[5]  
CARTER DR, 1978, CLIN ORTHOP RELAT R, P192
[6]  
CHRISTOPOULOS E, 1992, ARCH OTOLARYNGOL, V118, P1164
[7]   MEDIAN MANDIBULOTOMY - A CRITICAL-ASSESSMENT [J].
DUBNER, S ;
SPIRO, RH .
HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 1991, 13 (05) :389-393
[8]  
KOMISAR A, 1988, Ear Nose and Throat Journal, V67, P521
[9]  
MCCANN KJ, 1994, J OTOLARYNGOL, V23, P210
[10]   TUMORS AND SURGERY OF THE PARAPHARYNGEAL SPACE [J].
OLSEN, KD .
LARYNGOSCOPE, 1994, 104 (05) :1-28