Hand-held dynamometry: Reliability of lower extremity muscle testing in healthy, physically active, young adults

被引:192
作者
Kelln, Brent M. [1 ]
McKeon, Patrick O. [1 ]
Gontkof, Lauren M. [1 ]
Hertel, Jay [1 ]
机构
[1] Univ Virginia, Dept Kinesiol, Charlottesville, VA USA
关键词
D O I
10.1123/jsr.17.2.160
中图分类号
R49 [康复医学];
学科分类号
100215 [康复医学与理疗学];
摘要
Context. Hand-held dynamometry (HHD) has been shown to be a reliable, objective way to obtain strength measurements in elderly and physically impaired subjects. Objective: To estimate the intratester, intertester, and intersession reliability of HHD testing of lower extremity movements in young, healthy subjects. Design: Repeated measures. Setting: Sports medicine laboratory. Participants: Nine males and eleven females (Mean age = 26 years). Measurements: Strength measures of 11 right lower extremity movements were taken by 3 different testers on 2 separate days using a HHD. Results: Intratester ICC range was .77 to .97 with SEM range of .01 to .44 kg. Mean intertester ICC range was .65 to .87 with SEM range of. 11 to 1.05 kg. Mean intersession ICC range was .62 to .92 with SEM range of .01 to .83 kg. Conclusions: HHD has the potential to be a reliable tool for strength measurements in healthy, strong subjects; however, there are noteworthy limitations with movements where subjects can overpower the testers.
引用
收藏
页码:160 / 170
页数:11
相关论文
共 32 条
[1]
Normative values for isometric muscle force measurements obtained with hand-held dynamometers [J].
Andrews, AW ;
Thomas, MW ;
Bohannon, RW .
PHYSICAL THERAPY, 1996, 76 (03) :248-259
[2]
MAKE TESTS AND BREAK TESTS OF ELBOW FLEXOR MUSCLE STRENGTH [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1988, 68 (02) :193-194
[3]
Reference values for extremity muscle strength obtained by hand-held dynamometry from adults aged 20 to 79 years [J].
Bohannon, RW .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (01) :26-32
[4]
Alternatives for measuring knee extension strength of the elderly at home [J].
Bohannon, RW .
CLINICAL REHABILITATION, 1998, 12 (05) :434-440
[5]
BOHANNON RW, 1986, ARCH PHYS MED REHAB, V67, P390
[6]
INTERRATER RELIABILITY OF HAND-HELD DYNAMOMETRY [J].
BOHANNON, RW ;
ANDREWS, AW .
PHYSICAL THERAPY, 1987, 67 (06) :931-933
[7]
TEST-RETEST RELIABILITY OF HAND-HELD DYNAMOMETRY DURING A SINGLE SESSION OF STRENGTH ASSESSMENT [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1986, 66 (02) :206-209
[8]
Hand-held dynamometer measurements obtained in a home environment are reliable but not correlated strongly with function [J].
Bohannon, RW .
INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 1996, 19 (04) :345-347
[9]
Measuring knee extensor muscle strength [J].
Bohannon, RW .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2001, 80 (01) :13-18
[10]
HAND-HELD COMPARED WITH ISOKINETIC DYNAMOMETRY FOR MEASUREMENT OF STATIC KNEE EXTENSION TORQUE (PARALLEL RELIABILITY OF DYNAMOMETERS) [J].
BOHANNON, RW .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (03) :217-222